5.3. Compressed air connection
Warning:
The compressed air must be clean, dry and free of oil.
The maximum permissible compressed air pressure is 7 bar (100 PSI).
Use an external filter and pressure regulator for this purpose.
The compressed air is connected to the power unit via an 1/8” NPT female nipple. An adapter
nipple (1/8 x ¼ BSP) is included in the supply. Connect the compressed air via a flexible or rigid
line. The line diameter depends on the air consumption. The minimum inside line diameter must
be 4 mm.
5.4. Mains voltage connection
Warning:
Make sure that the equipment is properly earthed.
The wall socket to be used must be easily accessible.
1. Check that the mains voltage corresponds with the value shown on the rating plate.
2. Plug the connection lead into the connector of the power unit.
3. Insert the plug into an earthed wall socket.
6. Putting into use
Warning:
If the gun is used for a long period of time and/or frequently, it is recommended to
wear ear protection.
1. Point the gun to the object to be cleaned (distance: 5 to 30 cm).
2. Pull the trigger (LED lights up more brightly).
Attention:
If the Top Gun will not be used for a longer period: Remove the plug from the wall
socket
Blow-off power adjusent
The air supply can be adjusted using the screw in the grip.
Screw counterclockwise: blow-off power increases.
Screw clockwise: