![Simco-Ion 6432e User Manual Download Page 29](http://html1.mh-extra.com/html/simco-ion/6432e/6432e_user-manual_1274762029.webp)
19-6432-M-01 Rev 4
26
4.1 Specifications
Model 6432e Blower
Input Voltage
24 VDC ±10%, 6W (max) or 24 VAC ±10%; 50/60 Hz, 6W (max)
Discharge
±1000-100V, <4 sec @ 1’ using 24 VAC, tested in accordance with ANSI/
ESD STM3.1-2006 (performance of the Model 6432 will be reduced slightly
when powered with 24 VDC)
Balance
±20V @ 1’ away
Ion Emission
Steady-state DC
Emitter Points
Tungsten wire; internally shielded; 5-year life
Airflow
49 cfm (typ)
Ozone
<0.005 ppm (24-hour accumulation)
LED Indicators
Green POWER; red ALARM
Connectors
24 VAC/VDC power input, 8-pin terminal block with 24 VDC input from
process equipment; 4-20 mA current loop FMS output and relay interface
Controls
On/off rocker switch
Operating Env.
Temperature 10-35°C (50-95°F); humidity 30-60% RH, non-condensing
Dimensions
5.3H x 5.0W x 2.3D in. (13.3 x 12.7 x 5.7 cm) without stand
Weight
16 oz (467g) without stand
Certifications
RoHS Compliant
14-1320-01 Transformer
Input Voltage
120 VAC, 60 Hz
Output Voltage
24 VAC, 60 Hz @ 450 mA, ±5%
Short Circuit
Protection
The power supply is provided with protection against short circuit by means
of a primary thermal fuse.
Dimensions
3.4H x 2.3W x 1.9D (87 x 58.5 x 48 mm)
Weight
1 lb (0.45 kg)
Certifications
RoHS Compliant
14-1330 Transformer
Input Voltage
230 VAC ±10%, 50 Hz
Output Voltge
24 VAC @ 750 mA, ±5%
Short Circuit
Protection
The power supply is provided with protection against short circuit by means
of a primary thermal fuse.
Dimensions
2.8H x 2.5W x 1.9D in. (72H x 63W x 49D mm)
Weight
0.8 oz (0.36 kg)
Summary of Contents for 6432e
Page 1: ...I O N I Z A T I O N S O L U T I O N S Point of Use Ionizing Blower Model 6432e User s Manual...
Page 6: ...19 6432 M 01 Rev 4 3 Figure 2 Back of Model 6432e Blower...
Page 12: ...19 6432 M 01 Rev 4 9 Figure 3 Mounting Stand Knobs Screws and 8 pin Terminal Block...
Page 15: ...19 6432 M 01 Rev 4 12 Figure 6 In tool Bracket Mounting Hole Locations on Underside of Bracket...
Page 28: ...19 6432 M 01 Rev 4 25 4 Specifications 4 1 Specifications 4 2 Dimensional Drawings...
Page 31: ...19 6432 M 01 Rev 4 28 4 2 Dimensional Drawings Blower with Benchtop Stand...
Page 32: ...19 6432 M 01 Rev 4 29 Blower with In tool Stand...
Page 33: ...19 6432 M 01 Rev 4 30...
Page 35: ...19 6432 M 01 Rev 4 32...
Page 36: ...19 6432 M 01 Rev 4 33 Notes...
Page 37: ...19 6432 M 01 Rev 4 34 Notes...