![Simco-Ion 6432e User Manual Download Page 19](http://html1.mh-extra.com/html/simco-ion/6432e/6432e_user-manual_1274762019.webp)
19-6432-M-01 Rev 4
16
Process Equipment Power Connection
Two pins on the eight-pin terminal strip on the rear of the Blower can
receive 24 VDC power from your process equipment. An included
terminal block (Simco-Ion p/n 18-2308) is used to connect 24 VDC
power to the Blower from your process equipment. The terminals
are designed to accept wiring between 22 AWG and 16 AWG.
When wiring the Blower directly to a 24 VDC source, observe the
maximum voltage and power requirements for the unit [24 VDC
(±10%), 400 mA DC maximum].
Use a small flatblade screwdriver to secure cables into the terminal
block. See figure below.
Figure 9. Use a Small Flatblade Screwdriver to Secure Connecting Cables
Pins
State
8
24 VDC return
7
+24V
6-1
Not used
Summary of Contents for 6432e
Page 1: ...I O N I Z A T I O N S O L U T I O N S Point of Use Ionizing Blower Model 6432e User s Manual...
Page 6: ...19 6432 M 01 Rev 4 3 Figure 2 Back of Model 6432e Blower...
Page 12: ...19 6432 M 01 Rev 4 9 Figure 3 Mounting Stand Knobs Screws and 8 pin Terminal Block...
Page 15: ...19 6432 M 01 Rev 4 12 Figure 6 In tool Bracket Mounting Hole Locations on Underside of Bracket...
Page 28: ...19 6432 M 01 Rev 4 25 4 Specifications 4 1 Specifications 4 2 Dimensional Drawings...
Page 31: ...19 6432 M 01 Rev 4 28 4 2 Dimensional Drawings Blower with Benchtop Stand...
Page 32: ...19 6432 M 01 Rev 4 29 Blower with In tool Stand...
Page 33: ...19 6432 M 01 Rev 4 30...
Page 35: ...19 6432 M 01 Rev 4 32...
Page 36: ...19 6432 M 01 Rev 4 33 Notes...
Page 37: ...19 6432 M 01 Rev 4 34 Notes...