background image

E

N

SC

3

0

3

 &

 S

C

5

0

3

   

Sampling rate

100ms

Resistance inputs

Range

0 Ohm–65kOhm

Accuracy

±3%

Temperature sensor – NTC 10k

Range

From –15 to +80°C

Accuracy (from –10 to +60°C, from 14 to 140°
F)

±3%

Connectivity

Up to

Batteries

1

Temperature sensors

3

Voltage sensors

2

SiCOM RJ9 sockets

2

Installation and dimensions

Dimensions

120 x 120 x 60 mm
4.72 x 4.72 x 2.36 in

Battery connection

M10 bolts

SC503

Operating

Voltage range

6–35V

Temperature range

From –20 to +70°C (from –4 to +158°
F)

Power consumption at 12V

Operating

1.2mA

Current measuring range

Per channel

0.01–700A

Accuracy

±0.6 %

Resolution

0.01A

Sampling rate

100ms

Maximal current

Continuous

500A

Peak current (<1min)

1000A

Peak current (<5min)

700A

Voltage drop at 300A

50mA

Maximal voltage on connections

35V

Voltage inputs

Range

0–75V

Accuracy

±0.2%

Resolution

1mV

Sampling rate

100ms

Resistance inputs

Range

0 Ohm–65kOhm

Accuracy

±3%

Temperature sensor – NTC 10k

Range

From –15 to +80°C

Accuracy (from –10 to +60°C, from 14 to 140°
F)

±3%

Connectivity

Up to

Batteries

1

Temperature sensors

3

Voltage sensors

2

SiCOM RJ9 sockets

2

Installation and dimensions

Summary of Contents for SC303

Page 1: ...S I M A R I N E SC303 SC503 USERS MANUAL V1 3 EN USER MANUAL V 1 3...

Page 2: ...w 4 4 Installation 4 4 1 Cables 4 4 1 1 Power cable 5 5 Connecting 5 5 1 SCX03 installed on the minus terminal of the battery 6 6 Technical specifications SC303 SC503 6 7 Troubleshooting 8 7 1 Negativ...

Page 3: ...s current up to 300A and suitable for maximal power of 3600W at 12V or 7200W at 24V Innovative combination of shunt and tank level module SC503 is a high precision combo shunt for PICO battery monitor...

Page 4: ...stall the shunt use the supplied voltage cables and find a place no further than 3 m away from the battery battery bank You can fix the shunt with the supplied screws using two holes on the bottom of...

Page 5: ...t voltage sensing input to a battery terminal 4 Connect the temperature sensor to the shunt and place it near the battery battery bank optional 5 Connect the battery battery bank minus or plus termina...

Page 6: ...e From 20 to 70 C from 4 to 158 F Power consumption at 12V Operating 0 8mA Current measuring range Per channel 0 01 320A Accuracy 0 6 Resolution 0 01A Sampling rate 100ms Maximal current Continuous 30...

Page 7: ...0 to 70 C from 4 to 158 F Power consumption at 12V Operating 1 2mA Current measuring range Per channel 0 01 700A Accuracy 0 6 Resolution 0 01A Sampling rate 100ms Maximal current Continuous 500A Peak...

Page 8: ...he IN terminal on the shunt If this is not the case you can reinstall the shunt or simply switch the IN and OUT terminal via the shunt configuration on the PICO unit 7 2 Shunt is not visible on PICO I...

Reviews: