background image

PROCEDURE 

 

1.  Wait until the end of defrost cycle then 

disconnect power from the unit (

OFF

 

 

 
 
 

2. 

CLOSE

 water tap on the water supply line 

 
 

 

 

NOTE

: be sure no other equipment in use of water 

may suffer due to tap closure 

 

3.  Remove all ice from the bin. Either save it in a 

sanitary container or discard it. If routine 
sanitizing is due, the ice machine should be 
switched off during evening closing procedures 
to minimize waste during next morning sanitizing 
procedures. 

 

4.  Remove the front panel 

 

 

 

 

5.  Remove the drain plug and drain out the water 

 

 

 

6.  Carefully push upper sides corner of the 

evaporator plastic cover and withdraw the same  

 

 

 

7.  Gently push upper ice sensor arms and release 

the same from its bracket 

 

 

 

8.  Cut water inlet hose plastic clamp 
 

 

 
 
 
 

Summary of Contents for SV 145

Page 1: ...RST DE SCALE AND AFTER PROPER WASHING AND RINSING DO THE SANITATION WARNING When using any chemical protection of hands and eyes should be worn NOTE De scaling is recommended every 6 months in average...

Page 2: ...ary container or discard it If routine sanitizing is due the ice machine should be switched off during evening closing procedures to minimize waste during next morning sanitizing procedures 4 Remove t...

Page 3: ...t off to right hand thus to release the same from its bottom plastic bracket 11 Lift up and remove silicon cover 12 Cut water pump hose clamp and disconnect hose from its fitting 13 Push water level s...

Page 4: ...ater pump off from its seat 17 Push the two water sump holding brackets and withdraw water reservoir from its seat 18 Using gloves prepare the cleaning solution by diluting in a plastic bucket two lit...

Page 5: ...D starts slowly blinking this bring the unit at Cleaning cycle stand by MODE POWER OPER BIN FULL ALARM ALARM HI PRESS RE SET 26 Pour following quantity of cleaner inside water sump SV 145 205 300 ml S...

Page 6: ...e water drain valve for 40 seconds to drain out all remained water then both are de energized while water inlet valve remains energized open 33 Once water reservoir is filled up by water the water pum...

Page 7: ...by 1 of Amuchina sanitizer 41 Open the Ice storage bin 42 Fill up by mixed solution at 40 a spray bottle then spray the same to all bin internal wall area 43 With proper brush wipe all over bin insid...