ALARM TRANSMISSION TEST 

Shorting and disconnecting of SIM2W-FLOOD-I

 

sensor contacts pins unit enables the alarm 
transmission test feature. 
 
Check that the transceiver unit indicates at least 2 
events 

– one for shorting and one for 

disconnecting the SIM2W-FLOOD-I

 

sensor 

contacts. 
 
To check this function it is necessary to verify that 
the control panel displays the following message: 

 
 
 
 
 

 

 
 

 

TESTING THE DETECTOR 

Walk Test 

A. Set the control panel to "Walk Test Mode" as described 
in the Installer Manual. B. Make a momentary short 
between the two golden contacts pins of the sensor C. the 
alarm should appear on the control panel display.

 
 

Tamper Transmission Test 

Pressing and releasing the tamper (push button) enables 
the TAMPER transmission test feature. 
 
Verify the Control Panel indicates "Zone Tamper open" 
and TROUBLE LED is ON. 
 
Close the Tamper and verify the Control Panel Indicates 
ZONE TAMPER OPEN is restored and TROUBLE LED is 
OFF. 
 
In some control panels READY LED will turn OFF when 
tamper is open and ON when closed.  
 

Transmission can also be reviewed on the transceiver unit 
as a rapid Red-Green-LED blink.

 

 

 

 

 

 

 

BATTERY REPLACEMENT 

  Remove the front cover. 

 

  Pull out the old battery. 

 

  Install a new battery according to polarity marking. 

 

  After assembling the battery the LED will flash 

Green then Red alternately for 45 seconds. 
During this time the detector does not function, 
wait until the LED stop flashing. 

 

  Press tamper for 2 sec and then release it.  

 
 

Note:

  LED indications 

 

Green/Red LED flashes 6 times alternately:  
The detector was successfully registered in system.  
The cover may be placed back and closed. 

 

Green LED blinks 20 times:  
No response from Transceiver / device was not 
assigned on CP - Repeat installation procedure. 
 
Red LED blinks continually (over 20 sec):  
Battery voltage is critical low device won't 
function - Replace battery. 

 

16

 

 

17

 

 

18

 

TECHNICAL SPECIFICATIONS 

Data Protocol

 

Two Way Wireless

 

Frequency

 

868.35MHz

 

Identification

 

Unique ID serial number 
– 24 bit

 

Event Transmission

 

Alarm, Tamper, 
Supervision, Low Bat, 
Supervision

 

Detection Method

 

External golden 
contacts pins device

 

Range in open space

 

500m

 

Battery

 

Lithium. 3V Type: 
CR123A   Size: 2/3AA

 

Battery life

 

>5 years  
( 10 activation per day)

 

Current Consumptions

 

Standby ~3 

Receive mode ~29 mA  
Transmit mode~38 mA 

Low Battery

 

~2.4Vdc

 

Transmit power

 

~10dBm

 

Tamper Switch

 

Front Cover Removal; 
Back Tamper  

Operating temperature

 

10

C to +50

C

 

Dimensions

 

97mm x 22mm x 21mm

 

Weight (inc. battery)

 

40 gr.

 

 

 

CAUTION !!! 

 

RISK OF EXPLOSION IF BATTERY IS REPLACED BY DIFFERENT TYPE / MODEL.

 

 

DISPOSE USED BATTERIES ACCORDING TO ITS INSTRUCTIONS

 

 

 

 

 

 

 