background image

 

SIM-04 

DIGITAL DUAL DETECTOR 

PIR AND MICROWAVE 

 

 
 
 
 

 
 

 

 
 
 
 
 
 

INSTALLATION INSTRUCTIONS

 

P/N 7106762 Rev A 

Wide Angle Lens 

 

 

 

 
AVOID THE FOLLOWING LOCATIONS:

 

 

Facing direct sunlight. 

  Facing areas that may change temperature rapidly. 

  Areas where there are air ducts or substantial 

airflows. 

  Avoid screen, curtain that may block detection area. 

  Do not install outdoors. 

 

SPECIFICATION 

 
Detection Method 

PIR element & 

 microwave 

pulse 

Doppler 

Power Input 

8.2  to 16 Vdc 

Current Draw 

Active :    25.5 mA 

                                                Standby:  16.5 mA 

Temperature  
Compensation YES 

Alarm Period 

2 +/- 1  sec 

Alarm Output 

N.C 28Vdc 0.1 A 

with           

10 Ohm series 

protection  

resistors 

Tamper Switch 

N.C 28Vdc 0.1A 

with10 Ohm  

series protection 

resistor - open  

when cover is 

removed 

Warm Up Period  

1 min 

 

LED Indications 

Yellow blinking during warm up period and self 
testing  
 
Red LED: ON during alarm 
Green LED: PIR CHANNEL 
Yellow LED: MW CHANNEL 

 

Dimensions                   115mm x 61mm x 
37.5mm 

Weight                           120g 

 

INSTALLING THE DETECTOR 

 
 

Holding

Screw

Cover

Base

 

 

 

 

 

 

WIRE REQUIREMENTS

 

 

Use #22 AWG (0.5mm) or wires with a larger 
diameter. Use the following table to determine 
required wire gauge (diameter) and length of wire 
between the detector and the control panel. 

 

Wire Length       m     200    300    400     800 

Wire Diameter  mm    .5      .75      1.0     1.5 

Wire Length       ft      800   1200  2000   3400 

Wire Gauge       #       22      20      18       16 
 

PCB LAYOUT 

 