7.9 EN61000-3-2 harmonic current emissions.
If applicable to sales in Europe, the power supply shall meet the requirements of EN
61000-3-2 Class D and the Guidelines for the Suppression of Harmonics in Appliances
and General Use Equipment Class D for harmonic line current content at full-rated
power.
7.10 EN55022 Class B Radio interference (CISPR 22).
7.11 FCC Part 15, Subpart J class B 115VAC operation.
8. MTBF
8.1 MTBF (MEAN TIME BETWEEN FAILURES) CALCULATION
9. MECHANICAL REQUIREMENTS
9.1 Physical Dimension
150mm (W) × 86mm (H) × 160mm (D)
9.2 Connectors
M/B 24PIN connector
Orange(22AWG)
Blue (18AWG)
Green(18AWG)
Grey (18AWG)
Yellow/Black stripe
Yellow/Black stripe
Red (22AWG)
The demonstrated MTBF shall be 100,000 hours of continuous operation at 25 C,full
load,80% confidence limit and nominal line. The MTBF of the power supply shall be
calculated in accordance with MIL-STD-217D/E. The DC FAN is not included.