background image

03

 

AC Hot

AC Neutral

Power Supply

Vout

Vreturn

10uF

0.1uF

Load

Scope

AC Ground

Figure 1.  Ripple/Noise voltage test circuit

2.4 Overshoot

Any overshoot at turn on or turn off shall be less 10% of the nominal voltage value, all 

outputs shall be within the regulation limit of section 2.0 before issuing the power good 

signal of section 4.0.

2.5 Efficiency

2.5.1 

 Power supply typical  efficiency is 80% min under 20% Load / 50% Load / 100% 

Load at nominal input voltage of 115VAC .

2.5.2  Other Low Power System Requirements

To help meet the Blue Angel*, RAL-UZ 78, US Presidential executive order 13221, future  

EPA requirements, and other low Power system requirements, it is recommended that 

the +5VSB standby supply should be as efficient as possible. Standby efficiency is 

measured with  the main outputs off (PS_ON# high state). Standby efficiency should 

be greater than 50%  with a minimum loading of 100mA at input 115Vac. Pin   1W with a 

minimum loading of 50mA at input 230Vac.

2.6 Remote on/off control

When the logic level "PS-ON" is low, the DC outputs are to be enabled.

When the logic level is high or open collector, the DC outputs are to be disabled.

2.3.3 Ripple/Noise voltage test circuit

Summary of Contents for STRIDER SST-ST60F

Page 1: ...SST ST60F STRIDER SERIES...

Page 2: ...ge input capability and forced air cooling characteristics 1 AC INPUT REQUIREMENTS The input voltage current and frequency requirements for continuous operation are stated below 90 100 240 265 VACrms...

Page 3: ...supported for a minimum of 12 second 5 Maximum combined current for the 12V outputs shall be 48A 2 3 DC Output Ripple Noise 2 3 1 Ripple regulation mVp p mVp p mVp p mVp p mVp p 2 3 2 Definition The r...

Page 4: ...ower System Requirements To help meet the Blue Angel RAL UZ 78 US Presidential executive order 13221 future EPA requirements and other low Power system requirements it is recommended that the 5VSB sta...

Page 5: ...e point fault shall be able to cause a sustained under voltage condition on any or all outputs The supply shall provide latch mode under voltage protection as defined in Table 3 4 Over Current Protect...

Page 6: ...tor less than 110 for the critical components is recommended before the power supply is shut down Temperature derating factors higher than 110 can be evaluated on a case by case basis 4 TIMING 4 1 Sig...

Page 7: ...UL 1950 6 2 The power supply must bear the German Bauart Mark from TUV 7 0 ELECTROMAGNETIC COMPATIBILITY EMC 7 1 ELECTROSTATIC DISCHARGE ESD EN 61000 4 2 1995 7 2 ELECTRICAL FAST TRANSIENT BURST EFT...

Page 8: ...22 7 11 FCC Part 15 Subpart J class B 115VAC operation 8 MTBF 8 1 MTBF MEAN TIME BETWEEN FAILURES CALCULATION 9 MECHANICAL REQUIREMENTS 9 1 Physical Dimension 150mm W 86mm H 160mm D 9 2 Connectors M B...

Page 9: ...lack Yellow 12V2 6 2 COM Black 12V1 7 3 COM Black 12V1 8 4 COM Black Yellow Black stripe Yellow Black stripe ATX 12V 4PIN 18AWG wire Signal Pin Pin Signal 18AWG wire Black GND 1 3 12V1 Yellow Black GN...

Page 10: ...ue stripe Yellow Blue stripe Yellow Blue stripe 8PIN PCI Express connector 12V2 1 5 COM Black 12V2 2 6 COM Black 12V2 3 7 COM Black COM 4 8 COM Black 18AWG wire Signal Pin Pin Signal 22AWG wire Yellow...

Page 11: ...STRIDER SST ST60F 10...

Page 12: ......

Reviews: