02
3.1 OUTPUT VOLTAGE AND CURRENT
3. OUTPUT REQUIREMENTS
+12V1DC
+3.3V
+5V
+12V2DC
-12V
+5Vsb
1.0A
0.5A
0.3A
1.0A
0.0A
0.0A
MINIMUM
LOAD
7.0A
10.0A
7.0A
8.5A
0.4A
1.25A
NORMAL
LOAD
18A
28A
30A
18A
0.5A
2.5A
±5%
±5%
±5%
±5%
±10%
±5%
±1%
±1%
±1%
±1%
±2%
±1%
120mV P-P
50mV P-P
50mV P-P
120mV P-P
120mV P-P
50mV P-P
120mV P-P
50mV P-P
50mV P-P
120mV P-P
120mV P-P
50mV P-P
MAXIMUM
LOAD
LOAD
REG.
LINE
REG.
RIPPLE
NOISE
(1) +3.3V &+5V total output not exceed 180W.
When +3.3V is load to 28A,the +5V maximum load is 17.52A.
When +3.3V is load to 9.0A,the +5V maximum load is 30A.
(2) +12V1DC & +12V2DC total output not exceed 348W.
(3) +3.3V &+5V & +12V1DC & +12V2DC total output not exceed 385W.
(4) All outputs shall be safety-isolated from the AC mains and share a common return.
This common return must be connected to supply chassis.
(5) Voltages and ripple are measured at the load side of mating connectors with a 0.1 uF
monolithic ceramic capacitor paralleled by a 10 uF electrolytic capacitor across the
measuring terminals.