06
4.3 Over current protection
The power supply should contain the OCP function on each hot swap module. The power supply should be shut
down in a latch off mode while the respective output current exceeds the limit as shown in Table 8. When the latch
has been cleared by toggling the PSON# single or cycling the AC input power. The power supply module should
not be damaged in this condition.
4.4 Short circuit protection
5.1 Temperature
5.2 Humidity
6.1 Safety (Planning)
6.2 AC Input leakage current
The power supply shall shut down in a latch off mode when the output voltage is short circuit.
Input leakage current from line to ground will be less than 3.5mA rms. Measurement will be made at 240 VAC
and 60Hz.
Operating Temperature Range:
Non-Operating Temperature Range:
0°C ~ 40°C
-20°C ~ 70°C
Voltage
+5V
+3.3V
+12V
Minimum
110%
110%
110%
Maximum
160%
160%
160%
Shutdown Mode
Latch Off
Latch Off
Latch Off
Table 8 –Over Current protection
5. Environmental requirements
6. Agency requirements
Operating Humidity Range:
Non-Operating Humidity Range:
20% ~ 90%RH non-condensing
5% ~ 95%RH non-condensing
Product Safety:
UL60950-1/CSA 60950 (USA/Canada)
TÜV (CB) IEC60950 (report to include all country
national deviations)
EN60950-1(Europe)/IEC60950-1(International)
FCC(USA)
CE-low voltage directive 2006/95/EC(Europe)