After AC power is removed, the +5Vsb standby voltage output will remain at its
steady state value for the minimum hold-up time specified in Section 2.2.6 until the
output begins to decrease in voltage. The decrease can be monotonic in nature,
dropping to 0.0V. There are no other perturbations of this voltage at or following
removal of AC power.
2.3.9. +5Vsb at AC Power-down
2.4. Output Protection
ıĸ
2.4.1. Over Voltage Protection
The power supply can provide latch-mode over voltage protection as defined in
Table 12.
2.4.2. Under Voltage Protection
The power supply can provide latch-mode Under voltage protection as defined in
Table 13.
2.4.3. Over Current Protection
The power supply can provide Over Current Protection as defined in Table 14.
Table 13. Under voltage Protection
Table 14. Over Current Protection
Output Min.
Nom.
Max.
Unit
+12VDC 13.4
15
15.6
Volts
+5VDC 5.74
6.3
7.0
Volts
+3.3VDC 3.76
4.2
4.5
Volts
Table 12. Over Voltage Protection
Output Max.
Unit
+12VDC 9.80
Volts
+5VDC 4.47
Volts
+3.3VDC 2.83
Volts
Output Max.
+12V DC
150%
+5V DC
180%
+3.3V DC
180%
+5Vsb DC
250%,(7.5A)