ıĴ
Table 4. The power supply typical output load distribution
Table 5. The power supply typical output load distribution
Eup* requirements
In order to meet the 2010 and 2013 ErP Lot 6 requirements, AMS&2014 ErP Lot 3
requirements, and if any Computers use an Alternative Sleep Mode (ASM) then the
5V standby efficiency should be met as shown in Table 5 which is measured with
the main outputs off (PS_ON# high state).
2.2.4. DC Output Ripple & Noise
The output ripple & noise specifications listed in Table 8. will meet throughout the
load ranges as specified in section 2.2.2 and the nominal line input voltage
conditions as specified in section 2.1. Ripple & noise is defined as periodic of random
signals over a frequency band of 10Hz to 20MHz. Measurements should be made
with an oscilloscope with 20MHz bandwidth. adding a 10uF electrolytic capacitor
and a 0.1uF ceramic capacitor across output terminal during ripple & noise
measurement.
+12V
+5V
+3.3V
-12V
+5Vsb
Unit
Max
Ripple
&
Noise 70 30 30 40 40
mV
P
-
P
Table 8. DC Output Ripple & Noise
LOAD +12V +5V
+3.3V
-12V
+5VSB
SPEC
1200W
20%
17.53A 3.17A 3.17A 0.05A 0.52A
87.0%
50%
43.84A 7.925A 7.925A 0.13A 1.32A
90.0%
100%
87.68A 15.85A 15.85A 0.26A 2.63A
87.0%
1000W
20% 14.64A 2.54A 2.54A
0.05A
0.53A
87.0%
50% 36.59A 6.35A 6.35A
0.13A
1.32A
90.0%
100% 73.19A 12.70A
12.70A 0.26A 2.63A
87.0%
5VSB Load Target
5VSB Actual Load
Efficiency Target
(both 115V and 230V input)
Remark
45mA
≥
45%
ErP* Lot 6 2013
90mA
≥
55%
Recommend
0.55A
≥
75%
ASM and ErP* Lot 3 2014
1.00A
≥
75% Recommend
1.50A
≥
75%
ASM and ErP* Lot 3 2014
Max / Label
3.0A /Label
≥
75%
Recommend
Summary of Contents for DA1000R Gold