- 11 -
TThhe
e a
ap
pp
plliia
anncce
e d
do
oe
essnn''tt w
wo
orrkk
• Is there possibly a power failure?
• Is the plug sitting firmly in the mains power socket?
• Is the circuit-breaker turned on in the residence?
• Is the power cable damaged? C
CA
AU
UTTIIO
ON
N!! Check
this only after you have removed the plug!
• Is the appliance possibly standing in direct sunlight
or close to a source of heat?
TThhe
e iinnssiid
de
e tte
em
mp
pe
erra
attuurre
e d
do
oe
ess nno
ott ssiinnkk d
de
ee
ep
p e
enno
ouug
ghh
• Is the door is properly closed?
• Is the appliance possibly standing in direct sun-
light or close to a source of heat?
• Is the temperature regulator
5
correctly set?
• Did you leave enough space around the appliance
when setting it up ?
TThhe
e iinnssiid
de
e tte
em
mp
pe
erra
attuurre
e iiss tto
oo
o llo
ow
w
• Is the temperature regulator
5
correctly set?
• Is the "Super Freeze" function activated?
TThhe
e a
ap
pp
plliia
anncce
e g
ge
enne
erra
atte
ess cco
onnssiid
de
erra
ab
blle
e nno
oiisse
e
• Have you set the appliance up correctly according
to these instructions?
• Does the appliance vibrate or does it hit on the
back somewhere?
• The sounds described in the chapter "Operating
noises" are harmless.
S
Sttrro
onng
g iicce
e ffo
orrm
ma
attiio
onn o
onn tthhe
e iinnssiid
de
e
• Is the door is properly closed?
• Check that the door seal is clean.
• Is possibly some stored food preventing the
correct closing of the door?
• Is the door being opened too often?
TThhe
e cco
om
mp
prre
esssso
orr rruunnss cco
onnttiinnuuo
ouussllyy
• Is the door is properly closed?
• Have you just frozen large quantities of food?
If yes, please allow the appliance a few hours
to regain the desired cooling temperature.
• Is the door being opened too often?
• Is the "Super Freeze" function activated?
C
Co
onnd
de
ennssa
attiio
onn ffo
orrm
mss o
onn tthhe
e ffrre
ee
ezze
err iinntte
erriio
orr ssuurrffa
acce
ess
• Is the weather particularly hot or humid? This can
cause increased condensation.
• Has the door been left open?
• Was the door opened very often or allowed to
stand open for an extended period?
C
Co
onnd
de
ennssa
attiio
onn ffo
orrm
mss o
onn tthhe
e ffrre
ee
ezze
err e
exxtte
erriio
orr ssuurrffa
acce
ess
• Is there especially high humidity at present? This
can cause increased condensation on the exterior
surfaces. As soon as the humidity decreases, the
condensation will disappear.
IItt ssm
me
ellllss uunnp
plle
ea
assa
anntt iinn tthhe
e ffrre
ee
ezze
err iinntte
erriio
orr
• Does the interior need to be cleaned?
• Are perhaps packaging materials causing the
smell?
Information about the refrigerant
This appliance contains the refrigerant Isobutane
(R600a). Isobutane is a naturally occurring, low-
polluting gas. Nevertheless, caution is advised, be-
cause Isobutane is a flammable gas. Therefore, you
must make sure that the pipes of the cooling circuit
cannot be damaged. Should it ever happen, you
must avoid sparks and open flames. Do not smoke!
Carefully ventilate the room!
Please contact the Service Hotline in conjunction
with this.
IB_STG 85 A1_49364_LB6 09.04.2010 14:10 Uhr Seite 11