3
2 INSTALLATION
2.1MOUNTING
UPRIGHT
.......
For overhead use, always install a safety cable that can hold at least 10 times the weight of
the fixture.
For overhead installation, the fixture must be always secured with a safety wire that can bear
at least 10 times the weight of the fixture
;
Secure the fixture with a safety cable through the
rear safety eye as shown.
Ensure that the structure (truss) to which you are attaching the fixture is secure
Hanging layout
2.2 POWER CONNECTIONS
This product has an auto-ranging power supply that can work with an input voltage range of
100
–240 VAC, 50/60 Hz.
AC Plug
Connection
Wire (U.S.
Wire(Europe)
Screw Color
AC Live
Black
Brown
Yellow/Brass
AC Neutral
White
Blue
Silver
AC Ground
Green/Yellow
Green/Yellow
Green