18
4 USING A DMX512 CONTROLLER
MARCO
No function
DIMMER
4.1
BASIC ADDRESSING
Connect all of the units in series using standard DMX512 signal cable or the IP65 rated cable
provided.
Set the DMX512 address in the
DMX
menu.
It is possible to have the same DMX address or independent addresses for each fixture.
4.2
CHANNEL ASSIGNMENT
Note: This product have three DMX512 channel configuration:
STAGE 1
,
BLOCK
,
ARC 1
and
ARC 1+D
STAGE 1
BLUE
GREEN
RED
Strobe speed (0-20Hz)
STROBE
No function
6
0
9
1
2
0
255
3
4
0
255
0
255
0
255
5
0
10
11
35
36
60
61
85
86
110
111
135
136
160
161
185
186
210
211
215
216
220
221
225
226
230
231
235
236
240
241
245
246
250
251
255
RED 100% / GREEN UP / BLUE 0%
RED DOWN / GREEN 100% / BLUE 0%
RED 0% / GREEN 100% / BLUE UP
RED 0% / GREEN DOWN / BLUE 100%
RED UP / GREEN 0% / BLUE 100%
RED 100% / GREEN 0% / BLUE DOWN
RED 100% / GREEN UP / BLUE UP
RED DOWN / GREEN DOWN / BLUE 100%
WHITE 1: 3200K
WHITE 2: 3400K
WHITE 3: 4200K
WHITE 4: 4900K
WHITE 5: 5600K
WHITE 6: 5900K
WHITE 7: 6500K
WHITE 8: 7200K
WHITE 9: 8500K
10
255
CHANNEL
FUNCTION
VALUE
(or STEP TIME when Customs 01-10 in Ch7 is activated)
(or FADE TIME when Customs 01-10 in Ch7 is activated)
2008.5.22