background image

 

 
 

Drawers:

 

To remove the Drawers on the drawer models for cleaning, simply open them fully, push the stop levers out of the way on the 

Cabinet Drawer Tracks while pulling the Drawer out.  To reinstall the Drawer, line up the Drawer Tracks on the cabinet and the 
Drawer and push the Drawer into the cabinet.  The Drawer Pan can be removed by lifting it out with the Drawer extended. 

 

Electrical Connections:

 

Be sure to check the data plate, located on the liner of the cabinet, for required voltage prior to connecting the unit to a power 
source.  The specifications on the data plate supersede any future discussion.   

 

The standard unit is equipped with an eight (8) foot power cord that requires a 115 Volt, 60 Cycle, 1 Phase 

properly grounded

 

electrical receptacle.  The power cord comes with a 3 prong plug for grounding purposes.  Any attempt to cut off the grounding 
spike or to connect to an ungrounded adapter plug will void the warranty, terminate the manufacturers responsibility and could result 

in serious injury. 

 

The circuit must be protected with a 15 or 20 ampere fuse or breaker.  The unit must be isolated on a circuit and not plugged into an 
extension cord. 

 

OPERATION

 

Initial Start Up:

 

After satisfying the installation requirements, the unit is ready to start.  The unit will start when the power cord is connected to the 

required power source.  If the compressor does not start when the unit is initially plugged in, check to make sure that the 

temperature control is not in the 'off' position.  Allow the unit to run a minimum of two hours before loading it with product.  When 

loading the unit with product, take care not to block the air flow at the back of the cabinet as this would affect the performance of the 
cabinet. 

 

Temperature Control:

 

The Temperature Control is located on the back wall of the cabinet liner and is factory set to maintain an average cabinet 
temperature of 0 Deg. F.  To obtain colder temperatures turn the Temperature Control knob clockwise and visa versa.  Allow the 

unit a minimum of one hour to respond to a control setting adjustment. 

 

Defrost:

 

Your Silver King unit is an automatic defrost unit.  No additional plumbing is required.  Automatic defrosting is accomplished by a 

defrost heater and timer.  Frost buildup on the evaporator coil is cleared at six hour intervals.  Defrost water is collected in a pan 

located in the compressor compartment where it is evaporated into the room air.  It is important that the unit be level so the 

condensate can drain properly. 

 

MAINTENANCE

 

Preventative maintenance is minimal although these few steps are very important to continued operation and maximizing the life of 

the appliance. 

 

Cabinet Surfaces:

 

The cabinet interior and exterior are stainless steel.  These surfaces should be cleaned periodically with a solution of warm water 

and mild soap.  After cleaning the surfaces should be rinsed with clean water and wiped dry with a soft cloth.  Stainless steel 

cleaners can also be used.  Should a surface become stained, do not attempt to clean with an abrasive cleaner or scouring pad.  
Use a soft cleanser and rub with the grain of the metal to avoid scratching the surface.   Always rinse well and dry after cleaning.  

Do not use chlorinated cleaners. 

 

Condenser

 

Periodically the Condenser Filter Screen must be cleaned.  On cabinets without a base, the Condenser Filter Screen is located on 
the bottom of the cabinet.  To remove it, simply pull it out the front of the unit using the Filter Screen Pull.  On cabinets with a base, 
the  Condenser  Filter  Screen  is  located  behind  the  Base  Grill.    Simply  remove  the  Base  Grill  to  gain  access  to  it.    Clean  the 
Condenser Filter Screen by rinsing it in a stream of water.  Dry the screen by tapping it on a counter or floor.  On the models without 
a base, replace the Condenser Filter Screen by placing it into the Filter Guides on the bottom of the unit and sliding it all the way to 
the rear of the cabinet.  On the models with a base, replace the Condenser Filter Screen by placing it onto the angled support and 
reattaching the Base Grill.  Do not operate the unit without the filter sreen installed! 
 

Door Gasket

 

The Door Gasket will collect dirt and should be wiped clean with a warm, mild soapy water solution to extend its life and assure 

maximum cabinet performance and life. 

MODEL 

SERIAL NO. 

DATE INSTALLED 

Summary of Contents for SKF48

Page 1: ...1 Specifications Subject to Change Without Notice 1600 Xenium Lane North Minneapolis MN 55441 3787 Phone 763 923 2441 Technical Manual and ReplacementPartsList Freezer MODELS SKF48 SHOWN SKF48B ...

Page 2: ...e observed Always avoid locating the unit adjacent to an oven heating element or hot air source which could adversely affect the performance of the unit The unit must be level For proper ventilation the bottom front of the unit must not be obstructed Legs Casters Models without a base come with Legs or Casters To install them tilt the unit and thread the Legs or Casters into the four Rivnuts in th...

Page 3: ... adjustment Defrost Your Silver King unit is an automatic defrost unit No additional plumbing is required Automatic defrosting is accomplished by a defrost heater and timer Frost buildup on the evaporator coil is cleared at six hour intervals Defrost water is collected in a pan located in the compressor compartment where it is evaporated into the room air It is important that the unit be level so ...

Page 4: ...3 ...

Page 5: ...a la conveniencia y facilidad de acceso pero debe seguir las siguientes pautas de instalación Siempre evite colocar la unidad cerca de un horno elemento calefactor o fuente de aire caliente que pueda afectar el funcionamiento de la unidad La unidad debe estar derecha o levemente inclinada hacia atrás Para lograr una ventilación adecuada la parte inferior de la unidad no debe estar obstruida Patas ...

Page 6: ...ados 0 Grado Fahrenheit Para obtener temperaturas más bajas gire la perilla de Control de temperatura en el sentido de las agujas del reloj y viceversa Espere un mínimo de una hora para que la unidad responda a un ajuste de control Descongelamiento Su unidad Silver King posee descongelamiento automático y no se requieren trabajos de plomería adicionales El descongelamiento automático se produce po...

Page 7: ...i suivent doivent être observés Évitez toujours de placer l unité dans le voisinage d un four d un élément chauffant ou d une source d air chaud qui affecterait le fonctionnement de l unité d une manière négative L unité doit être à niveau Pour avoir une ventilation correcte l avant inférieur de l unité ne doit pas être obstrué Pieds Roulettes L unité se présente avec des pieds ou des roulettes Po...

Page 8: ... l unité au moins une heure pour répondre à un réglage de fixation de régulation Dégivrage Votre unité Silver King est une unité à dégivrage automatique Aucune tuyauterie supplémentaire n est requise Le dégivrage automatique est accompli par un réchauffeur de dégivrage et une minuterie L accumulation de givre sur le serpentin de l évaporateur est dégagée à des intervalles de six heures L eau de dé...

Page 9: ...llortes Ihres neuen Silver King Gerätes sind Bequemlichkeit und Zugänglichkeit wichtige Kriterien folgendes muss jedoch beachtet werden Stellen Sie das Gerät nie direkt neben eine Wärmequelle wie einen Herd oder Heizkörper denn dies würde die Leistung des Gerätes beeinträchtigen Das Gerät muss eben stehen Die untere Vorderseite des Gerätes darf nicht abgedeckt sein damit eine ordnungsgemäße Belüft...

Page 10: ... im Uhrzeigersinn wollen Sie die Temperatur erhöhen drehen Sie ihn gegen den Uhrzeigersinn Das Gerät braucht mindestens eine Stunde um auf die neue Einstellung des Temperaturreglers zu reagieren Abtauen Ihr Silver King Gerät taut automatisch ab Dafür sind keine zusätzlichen Installationen nötig Das automatische Abtauen geschieht durch eine Abtauheizung und einen Timer Das Eis auf der Verdampfersch...

Page 11: ...10 ...

Page 12: ...11 REPLACEMENT PARTS LIST MODELS SKF48 SKF48B WHEN ORDERING REPLACEMENT PARTS PLEASE PROVIDE MODEL AND SERIAL NUMBERS ...

Page 13: ...12 FORM NO 25970 REV Y ...

Reviews: