background image

 

 
 

OPERATION 
Initial startup: 

After satisfying the installation requirements, the cream dispenser is ready to start. The unit will start when the power cord is 
connected to a live electrical receptacle.  If the compressor is not running when the unit is initially plugged in, check to make sure 

that the Temperature Control is not set to the ‘off’ position.  Allow the unit to run a minimum of two hours before loading it with 

product. 

 

Preparation For Use: 

Once the unit has achieved proper operating temperature, observe the procedures noted in the label on the door liner for loading 

cream into the cream dispenser.  When removing an empty Cream Container, be sure to push the Valve Slide in fully before pulling 

the Dispensing Tube out of the valve.  It may be easier to remove or install the Dispensing Tube in the valve by removing the Valve 
Insert first then removing or installing the Cream Container and Dispensing Tube.  The Dispensing Tube should be changed weekly.  

The end of the tube may need to be cleaned daily with a clean cloth to prevent buildup which could affect the dispensing of product. 

 

Temperature Control: 

The Temperature Control, located behind the back panel (see label on door liner), is factory set at the midpoint position, which will 

maintain an average product temperature of around 36 - 38 Deg F.  To access the Temperature Control, follow the instructions on 

the door liner. To obtain cooler temperatures turn the Temperature Control stem clockwise and vise versa with a flat blade 

screwdriver.  Allow the unit a minimum of six (6) hours to respond to a control setting adjustment if the product is in the cabinet. 
 

Defrost: 

The Silver King cream dispenser is a manual defrost unit.  The unit should be defrosted whenever the walls accumulate a frost bank 

that is 1/2 inch thick.  To defrost the unit, either turn the Temperature Control knob to the ‘off’ position or disconnect the power cord 
from the electrical receptacle, and open the door.  After the frost has melted or come loose from the cabinet walls, wipe out the 

cabinet interior.  Do not attempt to scrape or chisel off the frost as you could do irreparable damage to the unit. 

 

MAINTENANCE 

Preventative maintenance is minimal although these few steps are very important to continued operation and maximizing the life of 

the appliance. 

 

Cabinet Surfaces: 

The cabinet interior and exterior are stainless steel and should be cleaned periodically with a solution of warm water and a mild 

soap, rinsed and wiped dry with a clean soft cloth.  A stainless steel cleaner can also be used.  Should a surface become stained or 

discolored, do not attempt to clean with an abrasive cleaner or scouring pad.  Use a soft cleaner and rub with the grain of the metal 

to avoid scratching the surface.  Do not use chlorinated cleaners. 

 

Valve Assembly: 

To dis-assemble the valve for cleaning start by pushing in on the Valve Slide and pulling the Valve Insert up and out.  This will free 

up all of the valve parts.  The Valve Slide, Spring and Cap Sleeve will all be removable once the Valve Insert is removed.  Clean all 

valve parts with a solution of mild soap and warm water.  Rinse, dry and re-assemble.  The Valve Body must be cleaned in place as 

it is not readily removable. 

MODEL 

SERIAL NO. 

DATE INSTALLED 

Summary of Contents for SKCRM1

Page 1: ...1 Technical Manual and ReplacementPartsList CreamDispensers Specifications Subject to Change Without Notice 1600 Xenium Lane North Minneapolis MN 55441 3787 Phone 763 923 2441 MODEL SKCRM1 MODEL SKCRM2 ...

Page 2: ...ility are important considerations but the following factors must be observed When placing the unit on a counter the counter must be able to support a minimum of 100 pounds When placed on a counter the unit must be on the feet supplied If the feet are removed the unit will not operate properly and the warranty will be void There must be at least two 2 inches of clear space above the unit two 2 inc...

Page 3: ... unit a minimum of six 6 hours to respond to a control setting adjustment if the product is in the cabinet Defrost The Silver King cream dispenser is a manual defrost unit The unit should be defrosted whenever the walls accumulate a frost bank that is 1 2 inch thick To defrost the unit either turn the Temperature Control knob to the off position or disconnect the power cord from the electrical rec...

Page 4: ...a conveniencia y facilidad de acceso pero debe seguir las siguientes pautas de instalación Si coloca la unidad sobre un mostrador éste debe poder soportar un peso mínimo de 100 libras Si coloca la unidad sobre un mostrador debe estar apoyada sobre los pies provistas Si no instala las pies la unidad no funcionará correctamente y la garantía será nula Deje un espacio libre de al menos dos 2 pulgadas...

Page 5: ...eis 6 horas para que la unidad responda a un ajuste de control si hay productos dentro del gabinete Descongelamiento La Máquina Expendedora de cream Silver King Majestic es una unidad de descongelamiento manual La unidad debe ser descongelada cada vez que las paredes acumulen una capa de escarcha de un grosor de 1 24 centímetros 1 2 pulgada Para descongelar la unidad lleve el Control de Temperatur...

Page 6: ... être observés Quand vous placez l unité sur un comptoir le comptoir doit être capable de supporter un minimum de 100 livres Quand sur un comptoir l unité doit être dans les pieds fournie Si les pieds sont retirés l unité no fonctionne correctement et annulera la garantie L unité exige un espace dégagé d au moins 2 pouces de l espace au dessus de l unité 2 pouces derrière de l unité et ouvert en f...

Page 7: ...dre à un réglage de fixation de régulation si le produit est dans l armoire Dégivrage Le distributeur de crème est une unité de dégivrage manuel L unité doit être dégivrée chaque fois qu une couche de givre glace ayant une épaisseur de 1 2 pouce s est accumulée sur les parois Pour dégivrer l unité tournez le réglage de température jusqu à la position arrêt ou débranchez le cordon d alimentation de...

Page 8: ...sen aber auch folgende Richtlinien zur Installation befolgt werden Wenn das Gerät auf einen Tresen gestellt wird muß die Einrichtung mindesten ein Gewicht von 45 kg tragen können Wenn das Gerät auf einen Tresen gestellt ist das Gerät mussauf den Füsse beschreiben sein Wenn die Füsse abnehmen sind funktioniert das Gerät nicht eng und der Hersteller übernimmt keine Verantwortung und es kann zu ernst...

Page 9: ...raubenzieher Das Gerät braucht mindestens sechs Stunden um auf die neue Einstellung des Temperaturreglers zu reagieren Abtauen Die Sahneausgabemodelle muss manuell abgetaut werden Das Gerät sollte abgetaut werden sobald die Eisschicht an den Wänden 1 3 cm dick ist Um das Gerät abzutauen stellen dann entweder den Temperaturregler auf aus oder ziehen den Stecker aus der Steckdose und öffnenen Sie di...

Page 10: ...9 ...

Page 11: ...8 COMPRESSOR KIT 230V 10343 53 10343 53 9 ELECTRICALSKIT RELAYAND OVERLOAD 115V 10344 51 10344 51 9 ELECTRICALSKIT RELAYAND OVERLOAD 230V 10344 53 10344 53 10 GROMMETCOMPRESSOR MOUNT 20481 20481 11 DRIER 22677 22677 12 CONDENSER COIL 43684 43684 13 HEATEXCHANGER 25196 25196 14 FOOT 99730 99730 15 BACKPANEL 24905 25655 16 APRON 24906 25673 17 DRIPTRAY 25064 25668 18 DRIPTRAYGRID 27179 27180 19 HORI...

Page 12: ...11 FORM NO 26230 REV G ...