background image

 

 

Operation 

Initial Startup 

After satisfying the installation requirements, the cream dispenser is ready to start. The unit will start when the power cord is connected 
to a live electrical receptacle. This can be verified by checking the indicator panel on the front of the unit.  The indicator should display 
the current unit temperature.  If the unit does not start when the power cord is plugged in, make sure that the switch on the back of the 
unit is in the ‘on’ position. Allow the unit to run a minimum of two hours before loading it with product.  

It is completely normal for the 

exterior of the unit to feel warm while it is running.   
 
Indicator Panel 

The Indicator Panel contains a digital LED display that reads the product temperature 
during normal operation.  The four lower buttons on the Indicator Panel are for selecting 
portion sizes (small or large).  The upper button is used to reset the computer whenever 

the cream is refilled.  

This button must be pressed each time the 

cream is refilled

.  

Press and hold the REFILL button for 3 

seconds until the indicator flashes 00.

 

 

Preparation for Use 

Once the unit has achieved proper operating temperature, observe the procedures noted 
on the label located on the door liner for loading cream into the cream dispenser. When 
removing an empty bag of cream, be sure to push the Valve Slide in fully before pulling the 
Dispensing Tube out of the valve. It may be easier to remove or install the Dispensing 
Tube in the valve by removing the Valve Insert first then removing or installing the Cream 
Container.  The end of the tube may need to be cleaned daily with a clean cloth to prevent 
buildup which could affect the dispensing of product

.  After loading the creamer, press 

and hold the REFILL button for 3 seconds until the indicator flashes 00. 

 

 

Defrost: 

The Silver King cream dispenser is a manual defrost unit.  
The unit should be defrosted whenever the walls accumulate 
a frost bank that is 1/2 inch thick.  To defrost the unit, either 
turn the Power Switch to the ‘off’ position or disconnect the 
power cord from the electrical receptacle, and open the 
door.  After the frost has melted or come loose from the 
cabinet walls, wipe out the cabinet interior.  Do not attempt 
to scrape or chisel off the frost as you could do irreparable 
damage to the unit. 
 

MAINTENANCE 

Preventative maintenance is minimal although these few 
steps are very important to continued operation and 
maximizing the life of the appliance. 
 

Cabinet Surfaces: 

The cabinet interior and exterior are stainless steel and 
should be cleaned periodically with a solution of warm water 
and a mild soap, rinsed and wiped dry with a clean soft 
cloth.  A stainless steel cleaner can also be used.  Should a 
surface become stained or discolored, do not attempt to 
clean with an abrasive cleaner or scouring pad.  Use a soft 
cleaner and rub with the grain of the metal to avoid 
scratching the surface.  Do not use chlorinated cleaners. 
 
 

 

 

The REFILL button must be 

pressed for 3 seconds each 

time the cream is replaced 

 

Indicator Panel

 

The four lower buttons on 

the Indicator Panel are for 

selecting portion size

 

Calibration Button 

(See Calibration Instructions) 

Summary of Contents for SKBD105CW1

Page 1: ...ical Manual and ReplacementPartsList BeverageDispenser Specifications Subject to Change Without Notice 1600 Xenium Lane North Minneapolis MN 55441 3787 Phone 763 923 2441 MODEL SKBD105P CW1 FORM NO 36475 REV A ...

Page 2: ...e following factors must be observed When placing the unit on a counter the counter must be able to support a minimum of 100 pounds When placed on a counter the unit must be on the feet supplied If the feet are removed the unit will not operate properly and the warranty will be void There must be at least two inches of clear space above on the sides and behind the unit and open in front Correct se...

Page 3: ...moving the Valve Insert first then removing or installing the Cream Container The end of the tube may need to be cleaned daily with a clean cloth to prevent buildup which could affect the dispensing of product After loading the creamer press and hold the REFILL button for 3 seconds until the indicator flashes 00 Defrost The Silver King cream dispenser is a manual defrost unit The unit should be de...

Page 4: ...3 ...

Page 5: ...4 ...

Page 6: ...5 WHEN ORDERING REPLACEMENT PARTS PLEASE PROVIDE MODEL AND SERIAL NUMBERS ...

Page 7: ...e valve insert by pulling it straight up Cleaning Once removed the valve can be cleaned with a brush and warm soapy water or in a dishwasher The valve area in the dispenser should also be cleaned with a brush and warm soapy water Insert New Bag into Container Insert a new beverage bag into the container as shown Lock the tube into place at the bottom of the container ...

Page 8: ...centered to avoid kinking which could result in reduced product flow or leaking Install Valve Insert Push and hold valve slide while inserting the valve insert from above Cut Tube Cut the tube one inch below the valve Press REFILL Button Press and hold the REFILL button for 3 seconds display 00 to alert the dispenser that a new beverage bag has been installed ...

Page 9: ...ing 3 Restricted filter drier 4 Restricted capillary tube 5 Moisture in system 1 Call service technician 2 Call service technician 3 Call service technician 4 Call service technician 5 Call service technician Compressor short cycles 1 Erratic control thermostat 2 Faulty relay 3 Low voltage 4 Compressor draws excessive wattage 1 Call service technician 2 Call service technician 3 Contact power comp...

Page 10: ... technician Beverage leaking or not flowing 1 Tube kinked 2 Valve stuck 1 Remove valve and pull tube straight through valve area 2 Clean valve and valve area or call for service Ordering Parts Service Contact Silver King Refrigeration at 800 328 3329 for technical assistance Model__________________ Serial No ___________________ Date Installed__________________ ...

Page 11: ...10 ...