Menu ‚milking’
Including the dis-
play of milking
parameters
F6 Abna:
Manuel detachment of milking cups and start of
intermediate disinfection
F8 Stopp:
After detachment the process may be stopped
until hoses are lowered for disinfection
.
F4 Stim:
Switches off stimulation (for example for cows
having small teats)
F3 Hand:
Deactivates automatic detachment and skips pre-
stimulation
:
⬆
Hoses move upwards, for instance when touching
the ground
:
⬇
Hoses are lowered, for instance if too short (to
this end, pull gently)
Tierkennung:
entry/display of identification
+++:
Deactivates automatic for this milking box
Tore:
Menu for manual gate control
Status information in upper line:
=> (left side) milking box being populated
Central blue display area
-
Information about milking box containing a waiting cow
=> (right side) milking box being discharged
Right grey display area: Number of milking box
7.2. Setup Service menu
7.2.1. Table: Parameter settings
No
Para-
meter
Description parameter
Default
As is
min
max
1
Z13
Actuator down 1/10s
4
0
2
Z14
Actuator up 1/10s
7
0
3
Z33
Attachment 1/10s
100
0
4
Z8
Shaking off 1/10s
3
0
5
Z28
End of shaking off 1/10s
80
0
6
Z7
Shaking-off up 1/10s
5
0
7
Number of steps for shaking off
3
0
8
Z11
Pivot time 1/10 s
2
0
9
Z19
Container fill time 1/10s
100
0
©Siliconform GmbH & Co. KG, 2013, all rights reserved subject to technical changes (11.12.2013)