Error
Possible cause
Action
Unusually long idle time
after detachment
Failure of end switch on
cylinder (cable breakage,
defective)
Milking as possible
Call service
Hoses lower themselves
between the milking
times or withdraw during
milking without user in-
teraction
Leakage in line system,
cylinder or valve
Check for leakage
Optionally call service
Movements are carried
out although the hoses
have not been withdrawn
End switch on cylinder is
always on
Call service
Multilactor®
does not
start on its own or not at
all
Failure of knee switch
Disconnect knee switch and
start with the start button.
Replace knee switch
Pulsation does not work
-
Main filter for fresh air is
clocked
-
Controller is defective
-
Contamination in pulsator
Replace filter
Check LEDs of pulsator
valves
HINT: in case of a failure of
a pulsator valve it is never-
theless possible to milk by
connecting the hose of the
defective valve to a func-
tioning valve by means of a
T-connection piece.
-->Call service
No or insufficient vacu-
um
-
Upper valve on PSM is
closed
Open valve, check for
contamination, condensed
water, check membrane for
damage/wear, possibly
replace
Check LED on control valve
Y20
(see figure 7 of attachment)