TSM1285 Demo Board
TSM1285-EVB Rev. 1.0
Page 3
will occur. To de-assert the shutdown function,
press the button again and the conversions will
resume. Figure 5 shows what the GUI looks like
when the shutdown control function is enabled.
7) A shutdown between conversions function is
available by selecting the “Shutdown between
conversions” box. Refer to Figure 4. When
performing a continuous conversion, press the
“shutdown” button and then select the
“Shutdown between conversions” box. The
samples vs code and the FFT plot will update
after every conversion.
8) To perform a single conversion, press the “single”
button in the sampling section.
9) For details on the evaluation platform GUI, refer
to the “Touchstone ADC Evaluation Platform GUI”
user’s manual at:
www.silabs.com
.
.
Figure 4. TSM1285 Response with GUI
Sampling section
TSM1285 ADC section
Samples vs Code plot
FFT plot