Silicon Graphics SG1 User Manual Download Page 6

 

6. Installation and Warning

 

  
 

6-2 Installation :

 The power inverter should be installed in an environment   

 that meets the following requirements Dry 

– Do not allow water to drip on or   

 enter into the inverter. 
  
Cool 

– Ambient air temperature should be between 0and 40, the cooler the 

better.   
Safe 

– Do not install the inverter in a battery compartment or other areas 

where flammable fumes may exist, such as fuel storage areas or engine 
compartments. 
Ventilated 

–Keep the inverter a distance (as least 1 inch) away from  

surrounding things.Ensure the ventilation shafts on the rear and the bottom of 
the unit are not obstructed. 
Dust 

– Do not install the Inverter in a dusty environments. The dust can be 

inhaled into the unit when the cooling fan is working. 
Close to batteries 

– Avoid excessive cable lengths. 

 

Do not install the Inverter in the same compartment as batteries. 
Use the recommended wire lengths and sizes(8AWG). Do not mount the 
Inverter where it will be exposed to the gases produced by the battery. These 
gases are very corrosive, and prolonged exposure will damage the Inverter. 
  
  

WARNING!

 

  

Shock Hazard. Before proceeding further, carefully check that 

 

the Inverter is NOT connected to any batteries, and that all wiring 

 

is disconnected from any electrical sources. Do not connect the 

 

output terminals of the Inverter to an incoming AC source

  

CAUTION!!

 

This equipment is not ignition protected and employs components that tend 
to produce 
Arcs or sparks. To reduce the risk of fire or explosions, do not install in 
compartments Containing batteries or flammable materials or areas in which 
ignition protected equipment is required. 

CAUTION!!

 

To reduce the risk of electric shock and prevent premature failure due to 
corrosion, 
do not mount where exposed to rain or spray. 

CAUTION!!

 

To prevent fire, do not obstruct ventilation openings. Do not mount in a zero 
clearance 
compartment,overheating may result. 

11 

 
5-3  LED Indicator 

– Display function 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

10 

Summary of Contents for SG1

Page 1: ... Status LED 5 4 Electrical Performance 6 7 4 1 Specification SG1 6 4 2 Specification Solar Charger Controller 7 5 Introduction 8 10 5 1 Solar Generator SG1 8 5 2 Front view and side view 8 9 5 3 LED Indicator Display function 10 6 Installation and Warning 11 13 6 1 Installation 11 12 6 2 Follow these guideline 12 6 3 Inverter Operation 13 6 4 Battery Installation and Replacement 13 7 Symbols Expla...

Page 2: ...onal metal items such as rings bracelets necklaces and watches when operating with a lead acid batteries Doing so may cause short circuit and very high temperature which can melt metal items and even burn you 2 2 Features Modified sine wave output Output frequency50 Hz Input output fully reinforce isolated design High efficiency 75 Driving highly reactive capacitive loads at start moment Color ind...

Page 3: ...rsed polarity is not covered by the warranty 4 WARNING Operation of the inverter without a proper ground connection may result in an electrical safety hazard 3 2 Panel operation Front view A ON OFF switch Leave in the OFF position during installation B Over heat protection LED sparkles when product temperature gets high it would shut down automatically while temperature arrives 55 C 5 C C Overload...

Page 4: ...d short circuit protection 1 25 rated load current 60sec 1 5 rated loads current 5sec over load protection action 3 Rated load current short circuit protection action Self consumption current 6mA Charge circuit voltage drop 0 26V Load circuit voltage drop 0 15V Over voltage protection 17V 12V 34V 24V Work temperature Industry stage 35 C to 55 C Commercial stage 5 C to 50 C Boost charge voltage 14 ...

Page 5: ... design bulk absorption float Wide volt range operation 90 135V 180 265V Durable and corrosion resistant construction 9 Transformer isolated for safety Bypass function Emergency backup light LED function 20A PWM Solar charger controller function option Max 100Ah battery space USB port 5V 2A 5 2 Front view and side view 8 10 11 DO NOT use this 2nd DC terminal alone Please connect the main battery c...

Page 6: ...e recommended wire lengths and sizes 8AWG Do not mount the Inverter where it will be exposed to the gases produced by the battery These gases are very corrosive and prolonged exposure will damage the Inverter WARNING Shock Hazard Before proceeding further carefully check that the Inverter is NOT connected to any batteries and that all wiring is disconnected from any electrical sources Do not conne...

Page 7: ... Operation To operate the power inverter use the ON OFF switch on the Front panel to turn the power on Then the power inverter is ready to deliver AC power to your loads If there is several loads use turn them on separately after the inverter is ON in order to prevent OVP resulted from the surge power 6 3 1 Set the power switch to ON position Then the inverter will make self diagnosis and the LED ...

Page 8: ...d electronic equipment and batteries should be recycled at a facility capable of handing these items and their waste byproducts Contact your local authority for details in locating a recycle facility nearest to you Proper recycling and waste disposal will help conserve resources whilst preventing detrimental effects on your health and the environment 7 2 Recommend Accessories 7 2 1 PV Solar panel ...