![Silicon Graphics SG1 User Manual Download Page 2](http://html.mh-extra.com/html/silicon-graphics/sg1/sg1_user-manual_1271601002.webp)
1. Important Safety Instructions
WARNING!
Before using the Inverter, you need to read and save the
safety instructions.
When the photovoltaic array is exposed to light, it supplies
DC voltage to the PCE!
1-1. General Safety Precautions
1-1-1. Do not expose the Inverter to water, mist, snow, spray, or dust. To
reduce risk of hazard, do not cover or obstruct the ventilation shafts. Do
not install the Inverter in a zero-clearance compartment. Overheating may
occur.
1-1-2. To avoid a risk of fire and electronic shock, make sure that existing
wiring is in good electrical condition and not undersized. Do not operate
the Inverter with damaged or substandard Wiring.
1-1-3. There are some components in the inverter can cause arcs and
sparks. To prevent from fire or explosion, do not put batteries,flammable,
materials, or anything should be ignition
–protected around the inverter.
1-2. Precautions When Working with Batteries
1-2-1. If battery acid contacts skin or clothing, you shall wash it out with
soap and water immediately. If battery acid contacts your eyes, you shall
wash it out with cold running water for at least 20 minutes and get medical
attention immediately.
1-2-2. Never smoke or make a spark or flame in the vicinity of the battery
or the engine.
1-2-3. Do not drop a metal tool on the battery. The resulting spark or short-
circuit on the battery of other electrical part may cause an explosion.
1-2-4. Remove personal metal items such as rings, bracelets, necklaces,
and watches when operating with a lead-acid batteries. Doing so may
cause short circuit and very high temperature, which can melt metal items
and even burn you.
2
2. Features
Modified
sine wave output
Output frequency50 Hz
Input & output fully reinforce isolated design
High efficiency 75%
Driving highly reactive & capacitive loads at start moment
Color indicators show input voltage level
Loading controlled cooling fan
Advanced microprocessor
Protection: Input low voltage Overload Short circuit
Low battery voltage Input over voltage Over temperature
Overvoltage protection : 16.0V with LED Orange and long alarm
2-1. Working Condition & Application
2-1-1.
Working Condition:
Working temp.: -10
°C ~45°C
Storage temp.: -25
°C ~70°C
Working humidity: 20%~90% RH non-condensing
Not for wet location use
Indoor use only, unconditional
Storage temp., Humidity: -30
°C ~70°C/-22°F~+158°F,10~95% RH
Temp. Coefficient:
±0.05%°C(0~55°C)
Ingress protection rating:IP20
Pollution degree classification: class II
Maximum altitude rating: 2000M
Overvoltage category: II for PV input and AC output
The PV array should be earthed.
2-1-2. Application
Linear load :1000W and below
Inductive and capacitive load: 400W and below
The inverter output waveform is not sinusoidal .It can not be used for
Precision instruments !
Inductive load occurred a surger power at leat three times with its rate
power when it starts . Please note this principal when choose the
inverter !
Motor and impact drill etc. Load can not be used as the big power rush!
Recommend load : office equipment , Home entertainment electronics,
Lights ,etc.
3