Silicon Graphics SG1 User Manual Download Page 2

 
1. Important Safety Instructions

 

  
  

 

WARNING!

   

 

Before using the Inverter, you need to read and save the 

 

safety instructions. 

 

When the photovoltaic array is exposed to light, it supplies 

 

DC voltage to the PCE! 

  
 
 

1-1. General Safety Precautions

 

 1-1-1. Do not expose the Inverter to water, mist, snow, spray, or dust. To     
  reduce risk of hazard, do not cover or obstruct the ventilation shafts. Do   
  not install the Inverter in a zero-clearance compartment. Overheating may   
  occur. 
  
  1-1-2. To avoid a risk of fire and electronic shock, make sure that existing   
  wiring is in good electrical condition and not undersized. Do not operate   
  the Inverter with damaged or substandard Wiring. 
  
  1-1-3. There are some components in the inverter can cause arcs and   
  sparks. To prevent from fire or explosion, do not put batteries,flammable, 
  materials, or anything should be ignition

–protected around the inverter. 

  
  

  1-2. Precautions When Working with Batteries

 

  1-2-1. If battery acid contacts skin or clothing, you shall wash it out with    
  soap and water immediately. If battery acid contacts your eyes, you shall   
  wash it out with cold running water for at least 20 minutes and get medical   
  attention immediately. 
  
  1-2-2. Never smoke or make a spark or flame in the vicinity of the battery  
  or the engine. 
  
  1-2-3. Do not drop a metal tool on the battery. The resulting spark or short-  
  circuit on the battery of other electrical part may cause an explosion. 
  
  1-2-4. Remove personal metal items such as rings, bracelets, necklaces,  
  and watches when operating with a lead-acid batteries. Doing so may  
  cause short circuit and very high temperature, which can melt metal items  
  and even burn you. 
 

2

 

 
2. Features

 

  
 

Modified 

sine wave output  

 Output frequency50 Hz  
 Input & output fully reinforce isolated design  
 High efficiency 75%  
 Driving highly reactive & capacitive loads at start moment 
 Color indicators show input voltage level  
 Loading controlled cooling fan  
 Advanced microprocessor 
 Protection:  Input low voltage        Overload                    Short circuit  
                   Low battery voltage     Input over voltage     Over temperature    
 Overvoltage protection : 16.0V with LED Orange and long alarm 
  

  2-1. Working Condition & Application

 

  2-1-1. 

Working Condition:

 

           Working temp.:  -10

°C ~45°C 

           Storage temp.: -25

°C ~70°C 

            Working humidity: 20%~90% RH non-condensing 
            Not for wet location use 
            Indoor use only, unconditional 
           Storage temp., Humidity: -30

°C ~70°C/-22°F~+158°F,10~95% RH 

           Temp. Coefficient: 

±0.05%°C(0~55°C) 

            Ingress protection rating:IP20 
            Pollution degree classification: class II 
            Maximum altitude rating: 2000M 
            Overvoltage category: II for PV input and AC output 
            The PV array should be earthed.  
 
 2-1-2.  Application 
            Linear load :1000W and below  
            Inductive and capacitive load: 400W and below 
     
                  

The inverter output waveform is not sinusoidal .It can not be  used for   

                    Precision instruments ! 
                    Inductive load occurred a surger power at leat three times with its rate  
                    power when it starts . Please note this principal  when choose the   
                    inverter ! 
                    Motor and impact drill etc. Load can not be used as the big power rush!  

    
 Recommend load : office equipment ,  Home entertainment electronics, 
 Lights ,etc.   

Summary of Contents for SG1

Page 1: ... Status LED 5 4 Electrical Performance 6 7 4 1 Specification SG1 6 4 2 Specification Solar Charger Controller 7 5 Introduction 8 10 5 1 Solar Generator SG1 8 5 2 Front view and side view 8 9 5 3 LED Indicator Display function 10 6 Installation and Warning 11 13 6 1 Installation 11 12 6 2 Follow these guideline 12 6 3 Inverter Operation 13 6 4 Battery Installation and Replacement 13 7 Symbols Expla...

Page 2: ...onal metal items such as rings bracelets necklaces and watches when operating with a lead acid batteries Doing so may cause short circuit and very high temperature which can melt metal items and even burn you 2 2 Features Modified sine wave output Output frequency50 Hz Input output fully reinforce isolated design High efficiency 75 Driving highly reactive capacitive loads at start moment Color ind...

Page 3: ...rsed polarity is not covered by the warranty 4 WARNING Operation of the inverter without a proper ground connection may result in an electrical safety hazard 3 2 Panel operation Front view A ON OFF switch Leave in the OFF position during installation B Over heat protection LED sparkles when product temperature gets high it would shut down automatically while temperature arrives 55 C 5 C C Overload...

Page 4: ...d short circuit protection 1 25 rated load current 60sec 1 5 rated loads current 5sec over load protection action 3 Rated load current short circuit protection action Self consumption current 6mA Charge circuit voltage drop 0 26V Load circuit voltage drop 0 15V Over voltage protection 17V 12V 34V 24V Work temperature Industry stage 35 C to 55 C Commercial stage 5 C to 50 C Boost charge voltage 14 ...

Page 5: ... design bulk absorption float Wide volt range operation 90 135V 180 265V Durable and corrosion resistant construction 9 Transformer isolated for safety Bypass function Emergency backup light LED function 20A PWM Solar charger controller function option Max 100Ah battery space USB port 5V 2A 5 2 Front view and side view 8 10 11 DO NOT use this 2nd DC terminal alone Please connect the main battery c...

Page 6: ...e recommended wire lengths and sizes 8AWG Do not mount the Inverter where it will be exposed to the gases produced by the battery These gases are very corrosive and prolonged exposure will damage the Inverter WARNING Shock Hazard Before proceeding further carefully check that the Inverter is NOT connected to any batteries and that all wiring is disconnected from any electrical sources Do not conne...

Page 7: ... Operation To operate the power inverter use the ON OFF switch on the Front panel to turn the power on Then the power inverter is ready to deliver AC power to your loads If there is several loads use turn them on separately after the inverter is ON in order to prevent OVP resulted from the surge power 6 3 1 Set the power switch to ON position Then the inverter will make self diagnosis and the LED ...

Page 8: ...d electronic equipment and batteries should be recycled at a facility capable of handing these items and their waste byproducts Contact your local authority for details in locating a recycle facility nearest to you Proper recycling and waste disposal will help conserve resources whilst preventing detrimental effects on your health and the environment 7 2 Recommend Accessories 7 2 1 PV Solar panel ...