System Fans
007-5839-001
53
Replacing System Fans
This section describes how to remove or install a system fan.
Remove/Replace a Fan
1.
If you have not already done so, remove the chassis cover to access the fans, see the example
in
Figure 6-5 on page 54
.
2.
Turn off the power to the system and unplug the AC power cord.
3.
Remove the failed fan's wiring connectors from the serverboard.
4.
Remove and retain the four pins securing the fan assembly to the fan tray.
5.
Lift the assembly housing the failed fan from the fan tray and out of the chassis, see the
example in
Figure 6-6 on page 55
.
6.
Place the new fan into the vacant space in the fan tray, while making sure the arrows on the
top of the fan (indicating air direction) point in the same direction as the arrows on the other
fans in the same fan tray. See
Figure 6-7 on page 56
for a fan assembly example.
7.
Reconnect the fan wires to the exact same chassis fan headers as the previous fan.
8.
Reconnect the AC power cord, power up the system and check that the fan is working
properly before replacing the chassis cover.
Summary of Contents for Rackable C1104G-RP5
Page 1: ...SGI Rackable C1104G RP5 System User Guide 007 5839 001 ...
Page 3: ...007 5839 001 iii Record of Revision Version Description 001 June 2012 First release ...
Page 4: ......
Page 10: ......
Page 22: ......
Page 34: ......
Page 40: ......
Page 54: ......
Page 65: ...Power Supply 007 5839 001 51 Figure 6 4 Power Supply Remove Replace Example ...
Page 69: ...System Fans 007 5839 001 55 Figure 6 6 Remove Replace Fan Assembly Example ...
Page 74: ......