Table 1-2
cpower example command strings
Command
Status/result
# cpower system on
or
# cpower node on "r*i*n*"
Powers on all nodes in the system.
# cpower node status "r1i*n*"
Determines the power status of all nodes in rack 1 (except
CMCs).
# cpower system status
Provides status of every compute node in the system along
with all rack leaders.
# cpower node on "r1i*n*"
Boots any nodes in rack 1 not already online.
# cpower system off
or
# cpower system halt
Completely powers down
every
node in the system except the
admin. If you are administering the system remotely through
the RLC it may become unreachable (see the next example).
# cpower node halt "r*i*n*"
Shuts down (halts) all the blade enclosure compute nodes in
the system, but not the administrative controller server, rack
leader controller or other service nodes.
# cpower system off
and
# cpower system on
Reboots all rack leaders and nodes in a system.
# cpower node on r1i0n8
Command tries to specifically boot rack 1, IRU0, node 8.
# cpower leader status
Determines the power status of all rack leaders.
# cpower node off
"
r2i*n*
"
This command example issues an ipmi tool power-off
command to all of the nodes in rack 2.
Powering the System On and Off
007-6399-002
11
See the
SGI Management Center Administration Guide for Clusters
, (P/N 007-6358-00
x
)
for more
information on
cpower
commands and related
ipmi
style commands.
See the section “System Power Status” on page 17 in this manual for additional related console
information.
Summary of Contents for ICE XA
Page 1: ...SGI ICE XA System Hardware User Guide Document Number 007 6399 002 ...
Page 4: ......
Page 12: ......
Page 25: ...Powering the System On and Off 007 6399 002 7 Figure 1 4 Three Phase PDU Example ...
Page 32: ......
Page 65: ...SGI ICE XA Series D Rack 42U 007 6399 002 47 Figure 4 1 D Rack Front Lock Example ...
Page 72: ...54 007 6399 002 4 Rack Information Figure 4 4 E Cell Rack Assembly Example CDU on Left ...
Page 82: ......