3: System Overview
System Features and Major Components
The main features of the SGI ICE X series server systems are introduced in the following sections:
•
“Modularity and Scalability” on page 38
•
“Reliability, Availability, and Serviceability (RAS)” on page 45
Modularity and Scalability
The SGI ICE X series systems are modular, blade-based, scalable, high-density cluster systems.
The system rack components are primarily housed in building blocks referred to as blade
enclosure pairs. Each enclosure pair consists of a sheet-metal housing with internal IB backplanes
and six (shared) power supplies that serve two “blade enclosures”.
However, other “free-standing” SGI compute servers are used to administer, access and service
the SGI ICE X series systems. Additional optional mass storage may be added to the system along
with additional blade enclosures. You can add different types of stand-alone module options to a
system rack to achieve the desired system configuration. You can configure and scale blade
enclosures around processing capability, memory size or InfiniBand fabric I/O capability. The
air-cooled blade enclosure has redundant, hot-swap fans and redundant, hot-swap power supplies.
A water-chilled rack option expands an ICE X rack’s heat dissipation capability for the blade
enclosure components without requiring lower ambient temperatures in the lab or server room.
See Figure 4-3 on page 59 for an example water-chilled D-rack.
A number of free-standing (non-blade) compute and I/O servers (also referred to as nodes) are
used with SGI ICE X series systems in addition to the standard two-socket blade-based compute
nodes. These free-standing units are:
•
System administration controller
•
System rack leader controller (RLC) server
•
Service nodes with the following functions:
–
Fabric management service node
–
Login node
–
Batch node
–
I/O gateway node
–
MDS or OSS nodes (used in optional Lustre configurations)
Summary of Contents for ICE X
Page 1: ...SGI ICE X System Hardware User Guide Document Number 007 5806 004 ...
Page 4: ......
Page 10: ......
Page 14: ......
Page 27: ...Powering the System On and Off 007 5806 004 7 Figure 1 5 Three Phase PDU Examples ...
Page 36: ......
Page 78: ...58 007 5806 004 4 Rack Information Figure 4 2 Front Lock on Tall 42U D Rack ...
Page 80: ...60 007 5806 004 4 Rack Information Figure 4 4 Air Cooled D Rack Rear Door and Lock Example ...
Page 84: ...64 007 5806 004 4 Rack Information Figure 4 6 SGI ICE X Multi Cell M Cell Rack Array Example ...
Page 86: ......