30
007-6419-003
4: System Monitoring
Power Supply LED
There is a single bi-color LED (green/amber) to indicate the power supply status.
describes the different states of the LED.
Table 4-4
Power Supply LED States
LED State
Power Supply (PS) State
Off
No AC power to any PS.
Green
Output on and Ok.
Green, 1Hz blink
AC present (only 12VSB on). PS off or PS in cold redundant state.
Note
: This is the normal state for a redundant PS.
Green, 2Hz blink
PS firmware updating.
Amber
– PS critical event causing a shutdown/failure (OCP, OVP, fan failure)
– AC cord unplugged or AC power lost. A second power supply in
parallel still has AC input power.
Amber, 1Hz blink
PS warning events where the power supply continues to operate (high
temperature, high power, high current, slow fan). The system power
supply temperature has reached 63
º
C. The system will automatically
power-down when the power supply temperature reaches 70
º
C and
restart when the power supply temperature goes below 60
º
C.
Summary of Contents for SGI UV 30
Page 1: ...SGI UV 30 System User Guide 007 6419 003 ...
Page 4: ......
Page 8: ......
Page 10: ......
Page 12: ......
Page 35: ...Install the System into a Rack 007 6419 003 19 Figure 3 2 Installing the Inner Rails ...
Page 39: ...Check the Serverboard Setup 007 6419 003 23 Figure 3 4 Accessing the Inside of the Chassis ...
Page 51: ...Replacing a Power Supply 007 6419 003 35 Figure 5 3 Replacing a Power Supply ...
Page 53: ...Replacing Disk Drives 007 6419 003 37 Figure 5 4 Removing HDD Carrier from Chassis ...
Page 54: ...38 007 6419 003 5 Chassis Maintenance Figure 5 5 Removing Dummy Drive from Carrier ...
Page 57: ...Replacing System Fans 007 6419 003 41 Figure 5 7 System Fans ...
Page 58: ......
Page 66: ......
Page 68: ......