420903-
Essential Peel Instructions Manual-rev000
l
6
2.2
Disposable Tips
For safe, efficient and hygienic applications, the unit comes with disposable plastic tips. Two sizes are available:
§
Blue tip:
Gentle abrasion, ideal for fine skin and sensitive areas.
§
Green tip:
Stronger abrasion, ideal for thicker skin and non-sensitive areas.
IMPORTANT: It is very important to clean the handpiece with a dry paper tissue to remove loose crystals
before inserting a new disposable tip.
§
Choose the appropriate disposable plastic tip. Place on the handpiece so that it fits tightly.
§
Before using a plastic tip, make sure that it is in good condition, neither cracked nor damaged, and that it
has no sharp edges that
could
cause injury. The tip may be reused up to 5 times on the same client.
§
Keep tip with client file. Do not give the tip to client. Disinfect the used tip with alcohol, making sure it is
perfectly dry before proceeding with the microdermabrasion session.
IMPORTANT: Using a damaged tip will result in weak suction. If suction is weak, check the tip and
replace, if necessary.
2.3
Corundum Crystals
§
Corundum is a natural mineral with excellent abrasive qualities.
§
Corundum crystals are Al
2
O
3
(aluminum oxide)
pure at 99.24 % and highly uniform granulometry 120 µ
(microns).
§
It is not recommended to use crystals other
than those
supplied with
the
equipment. They may be harmful to
your clients and will damage your equipment.
WARNING: To avoid cross contamination, never use crystals more than once. Used crystals have lost
their abrasive properties and are contaminated.
How to replace the “clean crystal” bottle
§
ONLY WHEN EMPTY,
proceed to
remove
the
clean crystal bottle.
If
there
are
too
many
crystals
left in the
receptacle, use the vacuum hose to remove
the
before
placing
the new bottle in. Disconnect the large hose
from the handpiece and use it to vacuum the excess crystals.
§
Turn on the unit on to
maximum intensity, and use the vacuum hose to clean all crystal residues from the
clean crystal outlet. Turn the unit OFF.
§
Remove the new "clean crystal" bottle cap
(DO NOT REMOVE PROTECTIVE SEAL);
screw it in place.
§
If something is trapped in the small hose, there will be no crystal projection. If this happens:
o
Run the unit at full power (10) for 10 seconds while blocking both the hand piece opening and the air
hole (air inlet orifice # 11), located at the back of the unit. Repeat this procedure 3 times. If there still
is no crystal projection, repeat again at maximum intensity.
o
This procedure will remove all crystals and debris trapped in the hoses and prevent blockage.
IMPORTANT:
ü
When using a “new crystal” bottle, always empty or replace the “used crystal” container.
ü
At the end of each procedure, use alcohol wipes to remove excess
crystals
from the hand piece.
Summary of Contents for ESSENTIAL Peel