6.2 MODULE 2 - R
ATE
S
ETUP
P
ARAMETERS
(
2-rAtE
)
PARAMETER MENU
RATE ENABLE
Module 2 is the programming for the Rate parameters. For maximum input
frequency, Rate Enable should be set to
NO
when not in use. When set to
NO
, the
remaining rate parameters are not accessible. The Rate value is shown with an
annunciator of “
R
” in the Display Mode.
This selects the decimal point position for rate displays and any setpoint
value assigned to these displays. This parameter does not affect rate scaling
calculations.
RATE DECIMAL POINT
0.00000
0.000
0.0
0.0000
0.00
0
RATE SCALING INPUT VALUE
RATE SCALING DISPLAY VALUE
Enter the desired Rate Display Value for the Scaling Point.*
Enter the corresponding Rate Input Value for the Scaling Point.*
0
to
999999
0
to
99999.9
*For value entry instructions, refer to selection/value entry in the Programming
The Meter section.
USER INPUT ASSIGNMENT
The User Input Assignment is only active if the meter is programmed in the
Dual Count Mode and a selection of reset, store, store and reset, or inhibit is
selected in the User Input Function menu.
USER INPUT FUNCTION
SECURITY
CODE
USER INPUT
STATE
PROGRAMMING MODE ACCESS
0
not
Pro Loc
-----
Immediate access
>0
not
Pro Loc
-----
After entering security code
at
Pro CodE
prompt
>0
Pro Loc
Active
After entering security code
at
Pro CodE
prompt
>0
Pro Loc
Not Active
Immediate access
0
Pro Loc
Active
No access
0
Pro Loc
Not Active
Immediate access
USER INPUT
FUNCTION
PROGRAMMING MODE ACCESS
MODE
DISPLAY
No Function
NO
DESCRIPTION
User Input disabled.
Program Mode Lock-out
Pro Loc
Display Select
(Edge triggered)
d-SELECt
Advance once for each
activation.
Maintained Reset
rESEt
Level active reset of the
selected counters.
Store
StorE
Store and Reset
Stor-rSt
Inhibit
Inhibit
Inhibit counting for the
selected counter(s).
d-LEVEL
Edge triggered reset of the
selected counter(s) after
storing the count.
Count A
Count b
both A-b
See Programming Mode
Access chart.
Display Intensity Level
(Edge Triggered)
Freeze display for the selected
counter(s) while allowing
counts to accumulate internally.
NO
USEr INP
Count A
USEr ASN
NO
RAtE Enb
001000
RAtE dSP
O
RAtE dP
01000.0
RAtE INP
Increase intensity one level
for each activation. (backlight
version only)
Shaded area selections only apply when programmed for dual count mode.
YES
NO