6.4  MODULE 4 - S

ETPOINT

O

UTPUT

P

ARAMETERS

(

4-SEtPt

)

PARAMETER MENU

The  Setpoint  Output  Parameter  is  only  active  when  the  optional  relay

module is installed in the meter.

Select the display the Setpoint is to be assigned.

SETPOINT OUTPUT ACTION

SETPOINT ASSIGNMENT

The 

yES

selection  allows  the 

SEL

button  to  toggle  through  the  enabled

displays.

FRONT PANEL DISPLAY SELECT ENABLE (SEL)

6.3  MODULE 3 - D

ISPLAY AND

F

RONT

P

ANEL

K

EY

P

ARAMETERS

(

3-dSPLAY

)

PARAMETER MENU

The 

yES

selection allows the 

RST

button to reset the selected counter(s). The

shaded  selections  are  only  active  when  the  meter  is  programmed  for  Dual
Count Mode.

FRONT PANEL COUNTER RESET ENABLE (RST)

The 

yES

selection  allows  the  display  to  automatically  scroll  through  the

enabled displays. The scroll rate is about every 4 seconds.

DISPLAY SCROLL ENABLE

Enter the desired backlight color, red or green. This parameter is active for

backlight units only.

DISPLAY COLOR (BACKLIGHT UNIT ONLY)

Enter the desired Display Intensity Level (1-5). The display will actively dim

or brighten as levels are changed. This parameter is active for backlight units only.

DISPLAY INTENSITY LEVEL (BACKLIGHT UNIT ONLY)

Programming a value other than 000, requires the security code to be entered

before  any  programming  changes  can  be  made.  This  parameter  can  be 
used  in  conjunction  with  the  Program  Mode  Lock-out  in  the  Input  Setup
Parameters section.

PROGRAMMING SECURITY CODE

The 

yES

selection  will  return  the  meter  to  the  factory  default  settings.  The

meter will display 

rESEt

and then return to 

Pro

, at which time all settings have

been changed.

Pressing the 

RST

key on power-up will load the factory settings and display

rESEt

. This allows operation in the event of a memory failure or corrupted data.

LOAD FACTORY DEFAULT SETTINGS

This parameter selects the action of the Setpoint output.

rAtE

Count A

LAtCH

t-OUt

bOUNd

NO

yES

Count b

both A-b
dSPLAy

yES
NO

NO

Count A

NO

yES

6rn

rEd

to

999

yES

NO

yES

SEL Enb

YES

RSt Enb

NO

d-ScroLL

rEd

d-COLOr

5

d-LEVEL

000

Pro CodE

MO

FACt SEt

Count A

SPt ASN

LAtCH

SPt ACt

to

5

Summary of Contents for Red lion CUB5

Page 1: ...e The CUB5 can be powered from an optional Red Lion Micro Line Sensor Power Supply MLPS1000 which attaches directly to the back of a CUB5 The MLPS1 is powered from 85 to 250 VAC and provides up to 400...

Page 2: ...inch lbs 0 565 N m max 10 CONSTRUCTION This unit is rated for NEMA 4X IP65 requirements for indoor use Installation Category I Pollution Degree 2 High impact plastic case with clear viewing window Pa...

Page 3: ...ar devices that generate excessive heat should be avoided The bezel should only be cleaned with a soft cloth and neutral soap product Do NOT use solvents Continuous exposure to direct sunlight may acc...

Page 4: ...SCR controls and heaters etc The cables should be ran in metal conduit that is properly grounded This is especially useful in applications where cable runs are long and portable two way radios are use...

Page 5: ...ven to the potential of the user input common with respect to earth ground and the common of the plug in cards with respect to input common AC Inputs From Tach Generators Etc Input A Two Wire Proximit...

Page 6: ...ed by pressing the SEL key with Pro NO displayed This will commit any stored parameter changes to memory and return the meter to the Display Mode If power loss occurs before returning to the Display M...

Page 7: ...or to achieve the desired display units feet meters gallons etc The Count Scale Factor Value can range from 00 0001 to 99 9999 It is important to note that the precision of a counter application canno...

Page 8: ...e User Input Function menu USER INPUT FUNCTION SECURITY CODE USER INPUT STATE PROGRAMMING MODE ACCESS 0 not Pro Loc Immediate access 0 not Pro Loc After entering security code at Pro CodE prompt 0 Pro...

Page 9: ...CALCULATION The meter determines the input frequency by summing the number of falling edges received during a sample period of time The sample period begins on the first falling edge At this falling e...

Page 10: ...LIGHT UNIT ONLY Enter the desired Display Intensity Level 1 5 The display will actively dim or brighten as levels are changed This parameter is active for backlight units only DISPLAY INTENSITY LEVEL...

Page 11: ...et SETPOINT OUTPUT RESET WITH MANUAL RESET This parameter enables the backlight CUB5 to switch the backlight color when the Setpoint Value is reached A reset will revert the backlight color to the nor...

Page 12: ...CUB5 PROGRAMMING QUICK OVERVIEW Shaded area selections are dependent on parameter mode selected Press and hold SEL key to enter Programming Mode...

Reviews: