Silge Electronica Red lion CUB5 Manual Download Page 1

1

G

LCD, REFLECTIVE OR GREEN/RED LED BACKLIGHTING

G

0.46" (11.7 mm) HIGH DIGITS

G

OPTIONAL RELAY OUTPUT MODULE

G

COUNT SPEEDS UP TO 20 KHZ (HIGH SPEED INPUT)

G

OPERATES FROM 9 TO 28 VDC POWER SOURCE

G

PROGRAMMABLE SCALING FOR COUNT AND RATE

G

BI-DIRECTIONAL COUNTING, UP/DOWN CONTROL

G

QUADRATURE SENSING (UP TO 4 TIMES RESOLUTION)

G

ANTI-COINCIDENCE COUNTING (ADD/ADD & ADD/SUB)

G

NEMA 4X/IP65 SEALED FRONT BEZEL

GENERAL DESCRIPTION

The  CUB5  provides  the  user  the  ultimate  in  flexibility,  from  it’s  complete

user  programming  to  the  optional  relay  output  capability.  The  meter  can  be
programmed  as  a  single  or  dual  counter  with  rate  indication  capability.  The
display  can  be  toggled  either  manually  or  automatically  between  the 
selected displays.

The CUB5 display has 0.46" (11.7 mm) high digits. The LCD is available in

two  versions,  reflective  (CUB5R000)  and  backlight  (CUB5B000).  The
backlight version is user selectable for green or red backlighting with variable
display intensity.

The  counter  is  programmable  for  one  of  eight  different  count  modes,

including  bi-directional  and  quadrature. When  programmed  as  a  dual  counter,
each counter has a separate scale factor and decimal points. In the counter/rate
indicator  mode,  each  have  their  own  scaling  and  decimal  point  read-outs  in
different engineering units.

The  meter  has  two  separate  inputs  which  provide  different  functions

depending on which operating mode is selected. Input A accepts the signal for
the Count and or Rate displays, while Input B accepts the signal for the Count
display  or  direction  control.  In  the  anti-coincidence  mode,  both  inputs  are
monitored simultaneously so that no counts are lost. The resulting display can
be  chosen  as  the  sum  or  difference  of  the  two  inputs.  The  Rate  Indicator  has
programmable  low  (minimum)  and  high  (maximum)  update  times  to  provide
optimal display response at any input frequency. There is a programmable user
input that can be programmed to perform a variety of functions.

The capability of the CUB5 can be easily expanded with the addition of an

option  module.  Setpoint  capability  is  field  installable  with  the  addition  of  the
CUB5RLY0, relay output module.

The  CUB5  can  be  powered  from  an  optional  Red  Lion  Micro-Line/Sensor

Power Supply (MLPS1000), which attaches directly to the back of a CUB5. The
MLPS1 is powered from 85 to 250 VAC and provides up to 400 mA to drive the
unit and sensors. 

COUNTER

The CUB5 receives incoming pulses and multiplies them by the Count Scale

Factor.  The  unit’s  counter  (internal  count  value) keeps  track  of  the  scaled  input
pulse count which results in the desired reading value for the count display. Input
A accepts the signal for the count and Input B is used for quadrature, dual counter,
anti-coincidence counting, or up/down control counting.

RATE

The rate indicator utilizes the signal at Input A to calculate the rate value using

a time interval method (1/tau). The unit counts on the negative edge of the input
pulses. After the programmed minimum update time elapses and the next negative
edge occurs, the unit counts the number or edges that occurred during the elapsed
time. The number of edges is multiplied by the rate scaling value to calculate the
rate value. At slower rates, averaging can be accomplished by programming the
rate minimum update time for the desired response. Extensive scaling capabilities
allow practically any desired reading at very slow count rates.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in this

literature  or  on  equipment  must  be  observed  to  ensure  personal  safety  and  to
prevent  damage  to  either  the  instrument  or  equipment  connected  to  it.  If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.

Do not use this meter to directly command motors, valves, or other actuators

not equipped with safeguards. To do so can be potentially harmful to persons or
equipment in the event of a fault to the meter.

MODEL CUB5 - MINIATURE ELECTRONIC 8-DIGIT DUAL 

COUNTER AND RATE INDICATOR

Bulletin No.  CUB5-X

Drawing No.  LP0584

Effective  8/04

CAUTION: Read complete

instructions prior to installation

and operation of the unit.

CAUTION: Risk of electric shock.

DIMENSIONS  In inches (mm)

Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.15" (54.6) H x 3.00" (76.2) W.

SILGE ELECTRONICA S.A.

                                         Av. Mitre 950 – B1604AKN - Florida  Tel. 4730-1001-Fax: 4760-4950
                                         Email: 

[email protected]

     Internet: http://www.silge.com.ar

Summary of Contents for Red lion CUB5

Page 1: ...e The CUB5 can be powered from an optional Red Lion Micro Line Sensor Power Supply MLPS1000 which attaches directly to the back of a CUB5 The MLPS1 is powered from 85 to 250 VAC and provides up to 400...

Page 2: ...inch lbs 0 565 N m max 10 CONSTRUCTION This unit is rated for NEMA 4X IP65 requirements for indoor use Installation Category I Pollution Degree 2 High impact plastic case with clear viewing window Pa...

Page 3: ...ar devices that generate excessive heat should be avoided The bezel should only be cleaned with a soft cloth and neutral soap product Do NOT use solvents Continuous exposure to direct sunlight may acc...

Page 4: ...SCR controls and heaters etc The cables should be ran in metal conduit that is properly grounded This is especially useful in applications where cable runs are long and portable two way radios are use...

Page 5: ...ven to the potential of the user input common with respect to earth ground and the common of the plug in cards with respect to input common AC Inputs From Tach Generators Etc Input A Two Wire Proximit...

Page 6: ...ed by pressing the SEL key with Pro NO displayed This will commit any stored parameter changes to memory and return the meter to the Display Mode If power loss occurs before returning to the Display M...

Page 7: ...or to achieve the desired display units feet meters gallons etc The Count Scale Factor Value can range from 00 0001 to 99 9999 It is important to note that the precision of a counter application canno...

Page 8: ...e User Input Function menu USER INPUT FUNCTION SECURITY CODE USER INPUT STATE PROGRAMMING MODE ACCESS 0 not Pro Loc Immediate access 0 not Pro Loc After entering security code at Pro CodE prompt 0 Pro...

Page 9: ...CALCULATION The meter determines the input frequency by summing the number of falling edges received during a sample period of time The sample period begins on the first falling edge At this falling e...

Page 10: ...LIGHT UNIT ONLY Enter the desired Display Intensity Level 1 5 The display will actively dim or brighten as levels are changed This parameter is active for backlight units only DISPLAY INTENSITY LEVEL...

Page 11: ...et SETPOINT OUTPUT RESET WITH MANUAL RESET This parameter enables the backlight CUB5 to switch the backlight color when the Setpoint Value is reached A reset will revert the backlight color to the nor...

Page 12: ...CUB5 PROGRAMMING QUICK OVERVIEW Shaded area selections are dependent on parameter mode selected Press and hold SEL key to enter Programming Mode...

Reviews: