Page 30
Silex
Using the SX-560
Part Number
140-00192-100
Configuring 802.1X EAP authentication can be complex. Please refer to Appendix A and/or
Appendix B for details of the required commands.
6. To set the serial ports, enter the following commands (If you are configuring Serial Port 2,
substitute the port name S2 instead of S1):
SET PORT S1 SPEED <baudrate>
[where <baudrate> is 300 to 921600]
SET PORT S1 PARITY <parity>
[where <parity> is ODD, EVEN, MARK, or
SPACE]
SET PORT S1 SIZE <databits>
[where <databits> is 7 or 8]
SET PORT S1 FLOW <flowcontrol>
[where <flowcontrol> is NONE, XON/XOFF,
CTS, or DSR]
The console commands are summarized in Appendix B of this manual.
7. When you have finished entering commands type:
INIT
EXIT
These commands will save the configuration and restart the unit. You are now ready to use the
SX-560.
EXIT
8. After an IP address and wireless network settings are configured in the SX-560, you can also
access the Internal Command Console in any of the following ways:
•
TELNET
. From the Windows Command Prompt (MS-DOS Prompt), Mac OS X Terminal
Utility, or UNIX/Linux command line, enter the command:
telnet
aa.bb.cc.dd
where aa.bb.cc.dd
is the IP address of the SX-560. Enter
admin
when you get the
login:
prompt, and then enter the password
access
. Then enter the command
./console
in
response to the Linux
#
prompt. When you get the
Local>
prompt, you are ready to enter
console commands.
•
Internal Web Pages.
Use a web browser to connect to the SX-560 internal web pages as
described earlier in this chapter. After you have logged in, click
Admin
on the left side of
the screen, and then click
Console
. You can now enter console commands (you must
click
Enter
after each command).
•
ExtendView.
Select the desired SX-560 from the ExtendView main menu. Click
Tools
on the menu bar, and then click
Telnet Session
. Enter
admin
when you get the
login:
prompt, and then enter the password
access
. Then enter the command
./console
in
response to the Linux
#
prompt. When you get the
Local>
prompt, you are ready to enter
console commands.
IMPORTANT:
The console command EXIT must always be used in order to save the changes you made with the internal
command Console.
Summary of Contents for Embedded Intelligent Module SX-560
Page 1: ...SX 560 Embedded Intelligent Module Developer s Reference Guide ...
Page 8: ...Page 2 Silex About This Reference Guide Part Number 140 00192 100 ...
Page 10: ...Page 4 silex Introduction Part Number 140 00192 100 ...
Page 24: ...Page 18 silex Installing the Evaluation Daughtercard Part Number 140 00192 100 ...
Page 72: ...Page 66 Silex Advanced Configuration Part Number 140 00192 100 ...
Page 78: ...Page 72 Silex Advanced Security Configuration Part Number 140 00192 100 ...
Page 100: ...Page 94 Silex Engineering Drawings Part Number 140 00192 100 ...
Page 104: ...Page 98 Silex SVL USB Firmware Part Number 140 00192 100 ...
Page 106: ...Page 100 Silex GNU Linux Programming Part Number 140 00192 100 ...
Page 108: ...Page 102 Silex Silex Contact Information Part Number 140 00192 100 ...
Page 109: ...Part Number 140 00192 100 Revision C 2 ...
Page 110: ...Part Number 140 00192 100 Revision C 2 Silex Technology America Inc www silexamerica com ...