5 Commissioning
Following correct mounting and wiring you can put the measuring system
into operation by switching on operating voltage.
6 Trouble shooting
Below are some typical errors which may occur during installation and
operation:
•
Magnetic tape wrongly mounted, active side below (see chapter
).
•
The masking tape provided was not used for protecting the magnetic
tape. The masking tape must not be magnetizable.
•
Magnetic sensor not or incorrectly connected (pin assignment see
•
The distance tolerances were not observed over the whole measuring
length (see
).
•
Cable squeezed / interrupted / cut by sharp edges.
•
The magnetic sensor has been mounted with the active side turned
away from the band (see
•
Magnetic sensor has not been aligned according to
7 Transport, Storage, Maintenance and Disposal
Transport and storage
Handle, transport and store the magnetic sensor with care. Pay attention
to the following points:
•
Transport and / or store the magnetic sensor in the unopened origi-
nal packaging.
•
Protect the magnetic sensor from harmful physical influences includ-
ing dust, heat and humidity.
•
Do not damage connections through mechanical or thermal impact.
•
Prior to installation inspect the magnetic sensor for transport dam-
ages. Do not install damaged magnetic sensors.
Maintenance
With correct installation according to chapter
the magnetic sensor
requires no maintenance. Clean the surface of the magnetic tape with soft
cloth from time to time if it is very dirty.