![Siko MSK400/1 Original Installation Instructions Download Page 20](http://html1.mh-extra.com/html/siko/msk400-1/msk400-1_original-installation-instructions_1270565020.webp)
MSK400/1
Installation English
MSK400/1 · Date
07.02.2018 · Art.
No.
81145 · Mod.
status
44/18
20
4.3 Mounting the magnetic sensor
Alignment of the magnetic sensor
`
Take care that the magnetic sensor is aligned correctly in order to
).
1. Mount magnetic tape (see chapter
).
2. Fasten the magnetic sensor, via the thru-holes (2x ø3.5 mm) on an
even work surface (for the fastening dimensions refer to the Data
Sheet). We recommend to use the enclosed fixing screws and washer
springs (fastening torque = 0.25 Nm).
LINEAR application:
MSK400/1 with MB400:
1
Active side magnetic tape
2
Travel direction signal A
before B
3
Direction of outgoing cable
4
Admissible deviation of
tape/sensor 0.1 ... 4 mm
5
Maximum alignment error
Fig. 6: Definition of the counting direction with magnetic tape and
assemblage sensor / magnetic tape, gap measure, tolerances
±3°
±3°
±3°
NOTICE