MA564
Installation English
MA564 · Date
03.04.2017 · Art.
No.
84321 · Mod.
status
264/16
19
4.4 Mounting the magnetic sensor
Alignment of the magnetic sensor
`
Take care that the magnetic sensor is aligned correctly in order to
ensure optimum sensing (see
Fig. 6
,
Fig. 7
).
1. Mount the magnetic tape (see chapter
4.3
).
2. Fasten the magnetic sensor, design L via the thru-holes (2x ø3.1 mm)
on an even work surface (for the fastening dimensions refer to the
Data Sheet).
Magnetic sensor design F can be mounted e. g. to a mounting square
with a corresponding mounting bore by tightening the two nuts
M8x0.5.
Design L:
1
Active side of the magnetic
tape
2
Admissible deviation of
tape/sensor 0.1 ... 2 mm
3
Maximum alignment errors
Fig. 6: Mounting sensor / magnetic tape, gap measure, tolerances
<1°
<3°
<3°
Design F:
1
Admissible deviation of
tape/sensor 0.1 ... 2 mm
2
Arrow
Fig. 7: Mounting sensor / magnetic tape, gap measure, tolerances
<3°
NOTICE