MA508SG
Commissioning English
MA508SG · Date
05.12.2014 · Art.
No.
88054 · Mod.
status
468/14
26
5.4 ERROR
As soon as the "ERROR" status occurs, position changes will no longer be
sensed.
The MA508SG is set to the "ERROR" no matter whether the display is
switched on or off. When the display is switched on, the "ERROR" status is
signalled on the display by a text of the same name.
Possible causes for the ERROR status:
1. Failure in the wire-actuated encoder or in the line to the wire-actuated
encoder.
Cancellation of the "ERROR" status:
Switch on the display (
key), position the sensor on the calibration
point and press the
key.
Using the "Reset Delay" parameter you can define wether the key should
respond to a short actuation or only after ~2 secs (touch protection).
Unless the LC display mode "have LCD always switched on" ("Lc.On") has
been programmed, the "ERROR" status directly influences the display
behaviour (see chapter
7
):
•
Switching on is only possible via the
key.
Summary of operating modes and key functions
Operating mode
Actuation time Key
Key
Key
Absolute measure-
ment
<1 sec.
Switch LCD on/
off (depending on
parameter LC-dis-
play mode)
Switching to
incremental
measure
Calibrate if Reset
Delay OFF
>2 sec.
Switching to
offset value
input
calibrate
Incremental mea-
surement
<1 sec.
Switching to
absolute mea-
sure
Calibrate if Reset
Delay OFF
>2 sec.
calibrate
Input offset value <1 sec.
Decrement offset
value
increment offset
value
>2 sec.
Offset value "-"
fast mode
Offset value "+"
fast mode
ERROR state
<1 sec.
Switch LCD on/
off (depending on
parameter LC-Dis-
play Mode
no function
Calibrate if Reset
Delay OFF
>2 sec.
calibrate
NOTICE
Summary of Contents for MA508SG