Siko LE200 + MB200 User Information Download Page 7

LE200+MB200 

Datum 09.11.2009 

Art.Nr. 84882 

Änd. Stand 326/09 

7

Fig.  7:  Definition  of  the  counting  direction  with 
magnetic strip and assemblage sensor/magnetic ring, 
gap measure, tolerances

Position of the reference point P = a 
stated in the delivery documentation

Position of the reference point E = as stated 
in the delivery documentation; min. 0,05m

Magnetic  poles 
- schema

Unique reference point

Periodical reference point

50

as short as 

possible

screening

5

viewing  side  = 
plug-in side

screening

screening

socket

pin

4.  Electrical connection

Check all lines and connections before switching 
on the equipment.

Interference and distortion

All connections are protected against the effects 
of interference. 

The location should be selected 

to  ensure  that  no  capacitive  or  inductive  in-

terferences  can  affect  the  sensor  or  the  con-

nection lines!

 Suitable wiring layout and choice 

of cable can minimise the effects of interference 
(e.g. interference caused by SMPS, motors, cyclic 
controls and contactors).

Necessary measures:

The sensor should be positioned well away from 
cables with interference; if necessary 

a protective 

screen or metal housing

 must be provided. The 

running of wiring parallel to the mains supply 
should be avoided.
Contactor coils must be linked with spark sup-
pression.

Supply voltage

The voltages depend on the sensor designs; they 
are to be taken from the delivery documentation 
and the identification plate.
 

e.g.: 

5VDC

4.1 Connection type
E1: 

Flying leads.

Attention!

 Tinned strands must not used in com-

bination with screw/clamp connections.

E6: 

With coupling (plug + socket).

Slip parts 6 to 10 over outer cable.
Strip cable.
Turn down screening.
Push part 5 onto ferrules.
Solder cable to part 3 (according connection 
diagram).
Open spacer (part 4) and put it over ferrules, 
squeeze and push it onto part  3. Slot and keyway 
of parts 3 and 4 must align.
Press  parts  6  and  5  together;  cut  prodruding  
screening.
Push parts 2 and 7 together and screw part 11 
using appropriate tool.
Push  part  8  into  part  9  and  slide  both  parts 
into part 7.
Screw parts 10 and 7 together.
Push part 1 into part 2.

1.
2.
3.
4.
5.

6.

7.

8.

9.

10.
11.

4.2 Pin outs

Without reference signal

 (7 pole plug pin)

PIN

Cable color

Signal

1

black

GND

2

red

sin

3

orange

/sin

4

yellow

cos

5

green

/cos

6

brown

+UB

7

- - -

- - -

Summary of Contents for LE200 + MB200

Page 1: ...e bzw der zu messenden Strecke erfolgen Welligkeiten ver schlechtern immer die Messgenauigkeit Aus technischen Gr nden muss bei der L nge gegen ber der Messstrecke ein Zuma von min 55mm ber cksichtigt...

Page 2: ...optimalen Schutz bietet die Montage in einer Nut Abb 5 die so tief sein sollte dass das Mag netband vollst ndig darin eingebettet werden kann Magnetbandlegen Hinweis BetrifftnurSensoren ohne Referenz...

Page 3: ...dzus tzlicheMa nahmen wie Schirmbleche oder metallisierte Geh use vorzusehen Leitungsf hrungen parallel zu Ener gieleitungen vermeiden Sch tzspulen m ssen mit Funkenl schgliedern beschaltet sein Spann...

Page 4: ...Power B rot Aktiv wenn cos cos C rot Aktiv wenn sin sin D rot Aktiv wenn ref ref 6 Wartung Die Ober che des Magnetbandes ist bei starker Verschmutzung durch Staub Sp ne Feuchtigkeit usw von Zeit zu Ze...

Page 5: ...hould be min 55mm longer than the actual measuring distance Attention To guarantee optimal adhesion oil grease dust etc must be removed by using clean sing agents which evaporate without leaving re si...

Page 6: ...There we recommend mounting accord to g 3 and 4 Mounting in a groove g 5 best protects the magnetic strip The groove should be deep enough to totally embed the magnetic strip When mounting the magneti...

Page 7: ...ld be positioned well away from cableswithinterference ifnecessary aprotective screen or metal housing must be provided The running of wiring parallel to the mains supply should be avoided Contactor c...

Page 8: ...enbach Unteribental Postanschrift Postal address Postfach 1106 79195 Kirchzarten Telefon Phone 49 7661 394 0 Telefax Fax 49 7661 394 388 E Mail info siko de Internet www siko de Service support siko d...

Reviews: