8
IV28M/1
Datum 23.07.2008
Art.Nr. 84362
Änd. Stand 40/08
Fig. 2: Wave form
OP
LD5
6.1 Wave form
SIKO GmbH
Werk / Factory:
Weihermattenweg 2
79256 Buchenbach-Unteribental
Postanschrift / Postal address:
Postfach 1106
79195 Kirchzarten
Telefon/Phone
+49 7661 394-0
Telefax/Fax
+49 7661 394-388
Internet
www.siko.de
Service
LD24
Note:
state of signals A and B in regards to the
reference signal 0 is not defined and can be diffe-
rent from fig. 2.
Attention!
Make sure that the follower electronics
can work with the corresponding pulse frequency.
max. pulse frequency:
36, 50, 100, 150 pulses:
20kHz
200 ... 800 pulses:
100kHz
850 ... 1000 pulses:
250kHz
Please be aware that pulses with the max. pulse
frequency may occur during machine stop
(due