Communication via CAN bus (CANopen and CANopen Safety)
IKM360M
Date: 21.01.2021
Art. No. 90444
Mod. status 222/20
Page 31 of 58
5.8
Directory of objects
5.8.1
Overview of objects
The following table offers an overview of the objects of the device.
Name
Description
See
page
1000h: Device Type
Device profile and inclinometer type.
1001h: Error Register
Current error state of the device.
1002h: Manufacturer Status
Register
Contains the Transmit Error Counter and the
Receive Error Counter.
1003h: Pre-defined Error Field The object stores the 8 error states that have
occurred last.
Setting of the COB ID of the SYNC object.
1008h: Manufacturer Device
Name
Device name in ASCII notation.
1009h: Manufacturer Hardware
Version
Indicates the hardware version of the device.
100Ah: Manufacturer Software
Version
Indicates the software version of the device.
100Ch: Guard Time
Parameter for Node Guarding.
100Dh: Life Time Factor
Parameter for Node Guarding.
1010h: Store Parameter
Object for non-volatile storage of the settings.
1011h: Restore Parameter
Object for restoring the factory settings.
1014h: COB ID Emergency
message
COB ID of the Emergency object.
1017h: Producer Heartbeat
Time
Setting of the cycle time of the heartbeat timer.
1018h: Identity Object
Contains the manufacturer number.
1200h: Server SDO Parameter
SDO Parameter.
1301h: SRDO1 Communication
Parameters
SRDO1 Communication Parameters.
1381h: SRDO1 Mapping
Parameter
SRDO1 Transmit Mapping Parameter.
Activate Safety configuration for SRDO1.
13FFh: Safety Configuration
Signature (checksum)
Signature (checksum) for SRDO1 configuration.
Transmit PDO for asynchronous transfer (timer
controlled).
Describes the arrangement of the objects, which
are mapped in TPDO1.
2000h: Digital filter cut-off
frequency
Defines the set filter time.
5F0Ah: Node ID and baud rate
Bus CAN
Setting of Node ID and baud rate.