AG26
Commissioning English
AG26 · Date
03.02.2022 · Art.
No.
87451 · Mod.
status
255/21
35
actuators we recommend that you connect grounding to a PE rail
1
(
Fig. 8: Ground bar
1
Admissible power input
Torque overloading
In case of massive, shock-type overloading, the actuator can be irrevers-
ibly damaged mechanically (e. g., block travel). When the actuator is over-
loaded, the motor current will be limited to the set value (for the proce-
dure of setting the current limit please refer to the user manual). Permanent
overload results in deactivation of the actuator (e. g., contouring error).
`
Adhere to max. admissible performance data as per chapter
.
`
Avoid block travelling.
`
Check drive transmission ratio.
`
Check existing torque (adjust acceleration/speed profile, see user
manual).
Supply for the actuator shall be sized sufficiently. When accelerating,
power input may be higher than nominal current for a short period. The
voltage values are a function of the device design and can be referred to in
the technical data in chapter
.
5 Commissioning
Latch-up effects
Output stage of the driver is damaged.
`
The operating voltage of the device must be switched on together with
the downstream electronics unit (e. g. control).
DANGER
NOTICE
WARNING