EtherHaul Operation, Administration and Maintenance Manual
Page 27
3.5.3
Rollback
A safety measure that allows recovering from system configuration changes that caused
loss of communication.
When Rollback is used, a timer runs (and restarts) whenever a management (or CLI)
command is entered. In the event that no command is entered within the timeout
period, the system automatically resets and comes up with the saved startup
configuration.
A Rollback timeout is especially recommended when configuring remote elements that
are being managed over the link.
Rollback is activated for both local and remote systems.
3.5.4
Reset
Separate buttons for local and remote reset. The system will reset and come up after
initialization (~120 seconds).
Note that any unsaved changes will be lost.
3.6
Copy To Remote
You can find the
Copy To Remote
button next to some configuration parameters or
sections. This function copies configuration to remote system based on the changes on
the local system.
Figure 3-5 Copy To-Remote icon
Matching configuration may be of two types:
Identical configuration – exactly same configuration will be copied from the
local to remote system. It can be found for parameters that normally
requires identical configuration for both local and remote units.
For example, Encryption configuration.
Matching configuration – for parameters that require matching but
opposite configuration.
For example (FDD systems): transmit frequency where Tx(local)=Rx(remote)
and Rx(local)=Tx(remote).