EtherHaul Operation, Administration and Maintenance Manual
Page 96
ref-clock eth1 prio
ref-clock eth1 status
ref-clock eth1 ql-actual
ref-clock eth1 ql-config
ref-clock eth1 ql-mode
ref-clock eth1 ssm-cvid
200
down
ql-dnu
ql-eec1
enable
none
ref-clock eth0 prio
ref-clock eth0 status
ref-clock eth0 ql-actual
ref-clock eth0 ql-config
ref-clock eth0 ql-mode
ref-clock eth0 ssm-cvid
200
down
ql-dnu
ql-eec1
enable
none
Line Failure
No incoming clock source on the local EtherHaul as line link is down.
The local EtherHaul switches to holdover mode (internal clock) while maintaining the
PRC clock accuracy it received previously and distributing it with its own quality level
(11: ql-eec1).
The remote EtherHaul receives and is locked on its Eth0 source and distributes timing
information from this source to its interfaces.
Figure 10-5 Typical SyncE Scenario
– Line Failure
The configuration for this scenario is:
Show ref-clock:
Local EtherHaul
Remote EtherHaul
ref-clock host prio
ref-clock host status
ref-clock host ql-actual
ref-clock host ql-config
ref-clock host ql-mode
ref-clock host ssm-cvid
255
backup-1
ql-eec1
ql-eec1
disable
none
255
backup-1
ql-eec1
ql-eec1
disable
none
ref-clock eth1 prio
ref-clock eth1 status
ref-clock eth1 ql-actual
ref-clock eth1 ql-config
ref-clock eth1 ql-mode
ref-clock eth1 ssm-cvid
200
active
ql-prc
ql-eec1
enable
none