6.5
Level and parameter operating menu
Display 1:
Level
Parameter
Note
1
Operating mode
1: A and B at a measuring chamber, possibility of return identification.
2
Volume unit
Selection of the volume unit. When "mass" unit, then calculation of the
density
3
Time unit
Conversion of the flow rate into the selected time unit.
4
Digits after the deci-
mal point Q
Number of digits after the decimal point for Q display: 0 to 3 digits
possible
5
Digits after the deci-
mal point V1 + V2
Number of digits after the decimal point for V1+V2 display: 0 to 3 digits
possible
6
K-factor A
Unit: Pulses per litre. This factor is used for sensor A.
12
Not used
13
Density in kg/m³
Density for operating conditions
24
Not used
Default setting: “OFF“.
25
Not used
34
Gate time flow display Period of time which the meter waits before updating the flow display.
35
Attenuation factor
Determination of the mean value via the last 1, 2, 4 or 8 mean values.
36
Total volume meter
reset
Password required to reset the total volume meter
45
Max. frequency
Display of the maximum recorded frequency. (Drag indicator function).
46
Not used
56
Software version
Display of the available software version
Display 2:
Level
Parameter
Note
1
Operating mode
1: A and B at a measuring chamber, possibility of return identification
2: A + B (measurement of the total volume)
3: A - B (measurement of the difference = consumption measurement).
2
Volume unit
Selection of the volume unit. When "mass" unit, then calculation of the
density
3
Time unit
Conversion of the flow rate into the selected time unit.
4
Digits after the deci-
mal point Q
Number of digits after the decimal point for Q display: 0 to 3 digits pos-
sible
5
Digits after the deci-
mal point V1 + V2
Number of digits after the decimal point for V1+V2 display: 0 to 3 digits
possible
6
K-factor A
Unit: Pulses per litre. This factor is used for sensor A.
12
K-factor B
Unit: Pulses per litre. This factor is used for sensor B.
13
Density in kg/m³
Density for operating conditions
24
Pulse output scaling 0: Original pulses of sensor A. (pulse duration original pulses: 4ms).
1: 1 pulse per change of the right-hand position of V1 (right).
2: 1 pulse per change of the second position … .
25
Pulse duration
Pulse duration. Period duration = 2x pulse duration. [4, 12, 24, 48, 100].
34
Gate time flow display Period of time which the meter waits before updating the flow display.
35
Attenuation factor
Determination of the mean value via the last 1, 2, 4 or 8 mean values.
36
Total volume meter
reset
Password required to reset the total volume meter
45
Max. frequency
Display of the maximum recorded frequency (Drag indicator function).
46
Not used
56
Software version
Display of the available software version