33
Sigur MR1
RECOMMENDED CABLE CHOICES
9.
If the readers are installed not far from the
controller (up to 50m), it is recommended
to use cables with cross-section of 0.22–
0.5mm².
Any types of signal cables can be used, such
as indoor signal cables 8х0.5.
If the readers are installed far from the
controller (50 to 100m), a cable with a
higher cross-section value (0.75-1.0mm²) is
recommended at least for the power supply
of the reader.
Before the connection, it is also
recommended to read carefully the
recommendations of the manufacturer of
your controller to which the reader will be
connected.