breakdown voltage, min, V
Surge protector triggering voltage
(differential), V
30
Arrester breakdown voltage (common-
mode), V
350
1.1.1 Maximum reach performance
Brief information about the maximum reach performance of the Sigrand SG-
16BV modem is shown on Table 2. The Bit Error Rate (BER) at the
maximum reach is equal to or less than 10
-7
. The specified reach is proved
by testing at the Sigrand lab reference line. Full version of the rate table is
available at our site
. An actual reach may vary against
the shown data due to variations of cable performance.
Table 2
Data rate
(kbps)
Line coding
Rating
TPP50-0.4
cable
(26 AWG)
TPP50-0.5
cable
(24 AWG)
6016
ТСРАМ32
Length (km/ft)
1.8/3500
2.2/7200
R (
Ω
)
476
420
4608
ТСРАМ32
Length (km/ft)
2.0/6500
2.6/8500
R (
Ω
)
560
455
3072
TCPAM16
Length (km/ft)
3.0/9800
4.2/13700
R (
Ω
)
840
736
2304
TCPAM16
Length (km/ft)
3.8/12400
5.4/17700
R (
Ω
)
1064
945
1536
TCPAM16
Length (km/ft)
4.4/14400
6.4/20100
R (
Ω
)
1232
1120
1024
TCPAM8
Length (km/ft)
5.0/16400
7.6/24900
R (
Ω
)
1400
1330
512
TCPAM8
Length (km/ft)
5.8/19000
9.0/29500
R (
Ω
)
1624
1575