The rate setup is performed by the
RATE rrrr
option (
“
rrrr”
stands for
rate in kbps). The rate is within 192 to 5696 kbps range with 64 kbps step:
: dsl rate 192
DSL: CFG=PREACT Rate=192 Code=TCPAM16 MASTER Annex=F - OFFLINE
: dsl rate 5696
DSL: CFG=PREACT Rate=5696 Code=TCPAM32 MASTER Annex=F – OFFLINE
:
To set a new value of the rate, enter the command at the “master” modem
only. The “slave” modem obtains the rate via G.hs Preactivation (ITU-T
G.994.1) protocol.
3.3.2.2 Setting DSL rate manually both sides
If the lower rates (64 to 128 kbps) or the higher rates (5696-6016) are
required, set the local control mode (
dsl cfg local
) for both modems. The
Annex type can be set A or F, if both modems have firmware version 2.5 or
higher. If one of the modems have firmware version 2.4 or lower (including
Granch SBNI16 modems), only Annex A should be used for compatibility (
dsl
annex a
).
: dsl cfg local annex a
DSL: CFG=LOCAL Rate=5696 Code=TCPAM32 MASTER Annex=A - OFFLINE
:
Manual rate setup is performed by the
RATE rrrr
option (
“
rrrr”
stands for
rate in kbps). The rate is within 64 to 6016 kbps range with 64 kbps step. The
rate should be set the same for both sides: