Lamps fail to operate when AC power is off
and generator power is on.
Doors fail to operate when AC power is off
and generator power is on.
Doors do not stay closed when manually
operated
Doors OPEN when AC power is ON
C
heck lamps are fully inserted in sockets.
Manually open doors and confirm movement is free with no resistance. If
movement is not free, check alignment of doors and hinges. Bent or buckled
doors will require factory replacement. If movement is free, check terminal
connectors on solenoid coil are in position and firm.
Close doors electrically. Switch off AC line power, switch on generator power,
then switch on AC line power to turn off generator power. After normal delay,
doors will close fully.
Check wire polarity connections to solenoid terminals as marked on frame:
RED: POSITIVE, BLACK: NEGATIVE.
TROUBLESHOOTING
FAULT CORRECTION
-6-