05.20
11
Josef Kihlberg JK20V779L
8
TROUBLE SHOOTING
FAULT
No staples when firing the tool.
Inadequate power. The staples do not penetrate
the material sufficiently.
Noise level is too high.
Jammed staple in the nozzle.
ELIMINATION
– Check that the right type of staples is being used
and moves easily inside the rail.
–
Always use Josef Kihlberg original staples.
– Check if the feeder spring is not defective. If
necessary replace.
– Check if the staple pusher is not defective. If
necessary replace.
– Clean the staple track.
– Air pressure too low. Secure that working pressure
is as recommend, see chapter 6.2
– Adjust the air pressure as chapter 6.2
– Has the tool been used without oil? Provide lubri-
cation, see chapter 5.2.
– Fit a longer driver blade.
– Check if the air pressure is correct. Adjust as per
chapter 6.2.
–
Ensure that the work piece is firmly held in place.
Vibration causes high sound levels.
– Open the door and remove the defective staple,
see chapter 7.3.
Before all trouble shooting tasks on
the stapler it must first be
disconnected from the air supply.