SignitePro C30000CLF Manual Download Page 6

6

PREPARING FOR INSTALLATION 

Before beginning assembly or operation of the product, make sure all parts are present.

Compare parts with package contents list. If any part is missing or damaged, do not attempt

to assemble, install or operate the product. Contact customer service for replacement parts. 

UNPACKING

 

1. 

Remove heater from carton. 

2. 

Remove all protective packaging applied to heater for shipping. 

3. 

Verify all contents are present.

4. 

If legs purchased separately, accessory bag contains: 

       Mounting Bracket × 1, Wood Screw (4x50) x 4, Screw (4.8x25) x 2, AAA Battery x 1,    

 

 

Rawl Plugs × 4, Spacer x 2 

5. 

Leg mount kit contains: Screw(3.9×13) × 4, Support Leg × 2

6. 

Check heater for any shipping damage. If heater is damaged, inform dealer immediately

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS 

Water vapor is a by-product of gas combustion. An unvented room heater produces approximately 

one (1) ounce (30 mL) of water for every 1,000 BTU (.3 Kw) of gas input per hour. An unvented room 

heater is intended as a supplemental heater rather than a primary heat source. In most supplemental 

heat applications, the water vapor does not create a problem. 

In most applications, the water vapor enhances the low humidity atmosphere experienced during cold 

weather. The following steps will help ensure that water vapor does not become a problem: 

1. 

Be sure the heater is the proper size for the application, including adequate combustion air and       

 

circulation air. 

2. 

If there is high humidity, a dehumidifier may be used to help lower the water vapor content of    

 

the air. 

3. 

Do not use an unvented room heater as the primary heat source.

Rawl Plug×4

AAA Battery×1

Spacer×2

Accessory bag

Support Leg×2

Leg Mount Kit (Optional)

Wood Screw

(4×50)×4

Mounting

Bracket×1

Screw ST

(4.8×25)×2

Screw ST

(3.9×13)×4

Summary of Contents for C30000CLF

Page 1: ...n from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air For Combustion and Ventilation section on page 7 of this manual INSTALLER...

Page 2: ...U hr 15 000 15 000 15 000 15 000 Fuel Type Natural Gas Natural Gas Propane Propane Natural Gas Natural Gas Propane Propane Ignition Electronic Push Button Electronic Push Button Electronic Push Button...

Page 3: ...ter will remain hot for a time after shutoff Allow surfaces to cool before touching WARNING Make sure any panel safety screen or guard removed for servicing an appliance is replaced prior to operating...

Page 4: ...in a bedroom These units are not approved for bathroom use 3 This heater needs fresh air ventilation to run properly This heater has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shut...

Page 5: ...ner on and off to maintain a desired room temperature For further information see page 20 State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth o...

Page 6: ...Water vapor is a by product of gas combustion An unvented room heater produces approximately one 1 ounce 30 mL of water for every 1 000 BTU 3 Kw of gas input per hour An unvented room heater is inten...

Page 7: ...LY TIGHT CONSTRUCTION The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide addi...

Page 8: ...as heater ___________ BTU hr Gas heater logs ___________ BTU hr Other gas appliances ___________ BTU hr Total ___________ BTU hr Do not include direct vent gas appliances Direct vent draws combustion...

Page 9: ...se items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Air for Combustion and Ventilation fo...

Page 10: ...ng wall than required CAUTION This heater creates warm air currents These currents move heat to wall surfaces next to the heater Installing the heater next to vinyl or cloth wall coverings or operatin...

Page 11: ...NOT dispose of batteries in fire Improper disposal may cause batteries to leak or explode PREINSTALLED FAN OPTIONAL WARNING This appliance is equipped with a three prong grounding plug for your prote...

Page 12: ...ts wire connected to the receptacle mounting screw ACCESSING FAN 1 Turn off gas supply to appliance 2 Remove appliance from mounted position if applicable 3 Remove screws connecting front heater cover...

Page 13: ...ION FAN WIRING ASSEMBLY DIAGRAM ELECTRICAL SCHEMATIC RED RED BLUE BLUE RED RED BLUE ON OFF AUTO SWITCH THERMAL SWITCH TO POWER CORD YELLOW GROUND YELLOW GROUND AUTO MANUAL OFF MOTOR AUTO MANUAL OFF TH...

Page 14: ...er will be placed for leg installation to prevent scratching of the table and or the heater Set back of heater on table with the bottom of heater extending outside the table edge Fasten Support Legs t...

Page 15: ...mounting Drill 5 16 in holes at least 1 in deep WARNING ELECTRICAL PLUMBING OR GAS LINES MAYBE IN WALL Before cutting drilling or hammering verify their location If needed contact your electrician plu...

Page 16: ...ppliance using 2 wall hanging spacer screws 4 8 x 25 Check that the spacers are secure before mounting appliance Spacer Wall Hanging Spacer Screw Fig 13 Locate Mounting Slots on upper left right of ap...

Page 17: ...line pressure is higher the unit will not work and heater regulator damage could occur CAUTION Never connect the heater directly to a LP supply This heater requires an external regulator not supplied...

Page 18: ...5 kPa Leak Testing Heater Gas Internal Connections 1 Open equipment shutoff valve see Fig 15 2 Make sure control knob of the heater is in the OFF position 3 Open gas supply tank valve LP systems 4 Che...

Page 19: ...y to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If y...

Page 20: ...ilot is visible centered below the burner behind the front grill see Fig 18 Do not attempt to light the pilot by hand 7 Keep control knob depressed for 30 seconds after pilot lights Release control kn...

Page 21: ...cool which shuts the heater off If pilot flame pattern is incorrect turn heater off see To Turn Off Gas to Appliance on page 21 see Troubleshooting pages 25 through 27 Ignitor Control Knob OFF P I L O...

Page 22: ...orrect Abnormal Flame Pattern with tall flames with Control Knob Set to High Flame Infrared Flame NOTE Before servicing you will need to remove the front panel of the heater There are 4 tapping screws...

Page 23: ...TION While the appliance is running press the switch to the MANUAL position see Fig 28 The fan will run continuously until turned to AUTO or OFF A DETAIL A SCALE 1 2 MANUAL Fig 28 MANUAL Switch Positi...

Page 24: ...servicing CAUTION You must keep the control areas burner and circulating air passageways of the heater clean Inspect these areas of the heater before each use Have the heater inspected yearly by a qu...

Page 25: ...lectrode is positioned wrong 2 Ignitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad ignitor or ignition mod...

Page 26: ...burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner orifice see Care and Maintenance on page 24 or contact customer service Burner backfiring...

Page 27: ...ontrol valve is defective 1 Locate and correct all leaks see Checking Gas Connections on page 18 2 Contact customer service Moisture condensation noticed on windows 1 Not enough combustion ventilation...

Page 28: ...L 1 1 10 Bracket of Furnace 1 1 1 1 11 Furnace Supporter 1 1 1 1 12 Ignitor Module 1 1 1 1 13 Ignitor Bracket 1 1 1 1 14 Front Grille 1 1 1 1 15 Support Leg 2 2 2 2 16 Spacer 2 2 2 2 17 Rear Side Oute...

Page 29: ...sponsible for any incidental indirect or consequential damages except as provided by law 6 All other warranties expressed or implied with respect to the product its components and accessories or any o...